TEST AND AJUSTMENT MANUAL
49-TPOSE-PSC-EN02
11
4.8. WEIGHT ADJUSTMENT.
Once the zero weight adjustment is made, the display will show a default weight, relative to the scale
capacity, to be used in the weight adjustment. This adjustment weight may be modified by using the
keyboard. Place a calibrated weight matching exactly the weight shown in the display on the weighing
platform and wait a few seconds for the weight to stabilize. Press the
key to begin the weight adjustment.
The display will show lines of hyphens while the adjustment is being done. This process will last for a few
seconds.
Once the adjustment process has been completed correctly, the scale will return to test ready automatically.
If an error occurs during the adjustment, press the
key to return to test ready and retry the adjustment
process.
Press
to modify the value of the flashing digit.
Press
to select the other digit.
Press
to go to the next parameter.