background image

10 

 

TROUBLE SHOOTING 

 
 
 

N° 

TROUBLE 

CAUSE 

CHECK / REPAIR 


 
 

The igniter does not function 
 

- The cable of igniter is disconnected 
 
- The igniter is damaged 

- Check and repair  
 
- Change (call a technician)  


 
 
 
 
 
 
 

The pilot burner does not light 
 
 
 
 
 
 
 

- Gas runs out 
 
- The gas line to pilot burner is closed  
 
- The hole of nozzle Tipp of pilot burner  
  is closed  
 
 

- Check and fill gas  
- Check and clean  
 


 
 
 
 

The burner flame is yellow  
 
 
 
 

- The primary air adjuster is closed 
 
- The burner is dirty  
 

- Check and open the primary air  
  adjuster  
- Clean with brush  

The burner does not light 

- The gas cock is damaged 

- Check and change  


 
 
 
 
 
 

The pilot flame lights but it 
extinguishes again 
 
 
 
 

- The thermocouple is slacked  
- The thermocouple does not produce  
   voltage (mv) 
- The thermocouple is dirty 
 

- Check and tight  
- Check with Milivoltmeter, if the  
  thermocouple is damaged,  
  change it  
 
- Check and clean 

 
 
 
 
 

Summary of Contents for TP-12/G

Page 1: ...Mod TPG3 15 Production code TP15 JG 01 2010 ...

Page 2: ...itchens VDI 2052 Regulations energy supply installations GVU 1 1 Directions For the installation and adjustment of the appliances as well as for the changes of the gas types an authorized technician must be called Sealed parts by the producer or authorized agent may not be touched by the technician During operation the appliance must be supervised 1 2 Place of Installation Setting Appliance The ap...

Page 3: ...ory connection pressure mbar 2 family 3 family Earthgas Liquid gas AT II2H3B P 20 50 BE II2E 3 20 25 28 30 37 CH II2H3B P 20 50 DE II2ELL3B P 20 50 DK II2H3B P 20 28 30 ES II2H3 20 28 30 37 FI II2H3B P 20 28 30 FR II2E 3 20 25 28 30 37 GB II2H3 20 28 30 37 GR II2H3 20 28 30 37 IE II2H3 20 28 30 37 IT II2H3 20 28 30 37 LU I2E 20 NL II2L3B P 25 28 30 NO I3B P 28 30 PT II2H3 20 28 30 37 SE II2H3B P 2...

Page 4: ...8 m3 h 18 3 m3 h TP 12 G 10 kW 4 kW 1 06 m3 h 1 23 m3 h 0 79 kg h 11 2 m3 h 12 2 m3 h TP 15 G 10 kW 4 kW 1 06 m3 h 1 23 m3 h 0 79 kg h 11 2 m3 h 12 2 m3 h TP 18 G 10 kW 4 kW 1 06 m3 h 1 23 m3 h 0 79 kg h 11 2 m3 h 12 2 m3 h The small combustion load is 2 8 kW for TP JG G each burner and 4 0 kW for TP G each burner This results in the following FLOW VALUES each burner TP JG G TP G Earth gas H E G20...

Page 5: ...osition MAX position MIN position 4 3 Closing of burner If the burner is only temporary to be cut the gas cock with handle must be placed clockwise into position so that the appliance remains operable For longer periods of interruption the gas cock with handle must be placed into position The main gas armature is to be closed 5 Important Notice The appliance is for commercial use and should be ope...

Page 6: ...ion occurs All gas pipes and parts must be controlled for closeness Slits of the burners and nozzles in the primary air segment must be free of foreign debris The gas armatures must be checked for easy of operation In case of heavy movements requires the exchange of these parts Application of grease in exceptional cases may only be done by the service engineer Sealed parts of the producer may not ...

Page 7: ...b GS 3875 2 3 4 2 By pass screw Ø 0 95 mm small flame GS 3687 2 3 4 3 Magnet for security Ø 10 5mm GS 8036 P 2 3 5 Piezzo igniter GS 3863 2 3 6 Spark plug cable 600 mm GS 3682 2 3 7 Spark plug GS 3856 2 3 8 Pilot burner DBL GS 3851 2 3 8 1 Pilot bracket GS 8042 P 2 3 8 2 Pilot head GS 8041 P 2 3 8 3 Pilot body GS 8040 2 3 8 4 Spring for pilot GS 8039 2 3 8 5 Nozzle for pilot GS 3828 2 3 8 6 Seal f...

Page 8: ...8 ...

Page 9: ...Fixing bush for primary air control assy 1 GS 2851 1 4 7 Nozzle Ø 1 4 mm Propangas 50mbar Nozzle Ø 2 5 mm Earthgas 20mbar GS 282 C GS 282 J 1 5 Safety Gas Cock GS 3875 1 6 1 ABS Knob for gas valve GS 3602 1 6 2 Label Ring for gas knob GS 3862 1 7 Pilot burner DBL GS 3851 1 7 1 Pilot haed 3 flames SP 385A 1 7 2 Pilot body with taking off screw fixing spring for nozzle SP 385B 1 7 3 Nozzle for pilot...

Page 10: ...ner is closed Check and fill gas Check and clean 3 The burner flame is yellow The primary air adjuster is closed The burner is dirty Check and open the primary air adjuster Clean with brush 4 The burner does not light The gas cock is damaged Check and change 5 The pilot flame lights but it extinguishes again The thermocouple is slacked The thermocouple does not produce voltage mv The thermocouple ...

Page 11: ...iquid gas 50 0 mbar 42 5 57 5 mbar Beyond these pressure ranges the appliance may not be operated 9 2 Technical data valid for EU The appliance is for operation of earth or liquid gas Construction A1 Country of destination Category Pressure ranges mbar 2 family 3 family Earth gas Liquid gas AT II2H3B P 20 50 BE II2E 3 20 25 28 30 37 CH II2H3B P 20 50 DE II2ELL3B P 20 50 DK II2H3B P 20 28 30 ES II2...

Page 12: ... G25 0 34 m3 h 0 49 m3 h Liquid gas G30 G31 0 22 kg h 0 32 kg h The appliance is operated in full combustion with fixed nozzles without prior adjustment For the main burner and pilot flame small combustion for liquid gas is obtained with fixed nozzle for earth gas the nozzle has to be regulated 9 4 Nozzle list Type of gas Pressure mbar type TP JG G type TP G burner Full combustion Minor combustion...

Page 13: ... take off the ABS knob Remove the nozzle from the nozzle carrier and replace a new nozzle according the nozzle table for use in the country of operation and gas type required The nozzle must be fixed with a non hardening sealing tape 10 Small combustion adjustment For the Combi Wok burner soup burner the small combustion adjustment must be regulated to 4 5 kW for earthgas The nozzle bore in the sm...

Page 14: ... gas L 25 mbar Liquid gas 28 30 37 mbar Liquid gas 50 mbar TP JG G H 14 mm 14 mm 14 mm 16 mm 14 mm TP G Nut B 15 mm 15 mm 15 mm 15 mm 15 mm Injector A closed closed closed closed closed Primary air adjustment types TP JG G Primary air adjustment types TP G 13 Tests After a conversion the following requirements must be fulfilled Nozzle diameter and pressure must be identical to the indication of th...

Page 15: ...ner is closed Check and fill gas Check and clean 3 The burner flame is yellow The primary air adjuster is closed The burner is dirty Check and open the primary air adjuster Clean with brush 4 The burner does not light The gas cock is damaged Check and change 5 The pilot flame lights but it extinguishes again The thermocouple is slacked The thermocouple does not produce voltage mv The thermocouple ...

Reviews: