Operator's guide
7. CONNECTION TO THE MAINS
1
2
3
4
5
N.B.:
8. CONTROLS
1. Cover lifting switch:
2. Light switch:
3. Refrigeration switch:
4. Thermometer
Thermostat:
5 “SET or P”
6 “UP”
7 “DOWN”
9. CHECKING CORRECT OPERATION
Make sure that: 1.
2.
3
4
5.
6
10. INTERNAL AND EVAPORATOR CLEANING
1.
2.
3.
4
5
6
. Ensure that mains voltage and frequency are the same as those stated on the rating plate (A) attached
to the appliance. . Ensure that the supply socket: a) is properly earthed; b) fulfils the requirements of the
rated current as set out on the rating plate; c) complies with the IEC regulations:- thermal-magnetic switch
with In = rated value as stated on the rating plate; - differential with Id sensitivity = 30 mA. . Ensure that
there is no danger of explosion (AD) in the room. . Make sure the environment is suitable for the power
supply cable provided. The cable of the appliance is H05 VVF, designed for internal use. For installation
in other than internal settings, it will be necessary to replace the cable with the appropriate type (for
example H07 VVF for external settings). . Insert the plug in the socket (do not use three-way adapters
and reduction adapters).
if the equipment has been transported or stored overturned, let is rest in
its correct position for at least 3 hours before hooking it up to the mains (see fig. 5).
The appliance features controls situated in a protected panel on the front side.
to
open and close the cover - Position II to lift - Position O to stop - Position I to lower.
to
switch on the internal lights.
to switch on the refrigeration unit.
: to read the temperature in the counter.
to adjust the temperature setting.
a) Press key
to display the temperature set-point, which can be changed by pressing key
or
(see fig. 6).
the plug is connected;
the refrigeration unit switch is on (green light lit up);
. thermometer shows the desired temperature for the goods to be stored; . appliance is not exposed to
direct sunlight or to powerful lamps;
ambient temperature does not 30°C with 55% R.H.
(climatic class 4); . there are no direct air draughts in the appliance, coming from the appliance itself,
owing to the presence of doors, windows, fans or conditioner outlets.
Switch off the appliance.
Check the evaporator fins for frost or ice. Should the layer of frost be too
thick, and ice drips are noted that could impair passage of air, complete defrosting should be undertaken.
Remove goods and store them in another suitable refrigerator running at the same temperature.
Remove the plug in the bottom section of the machine. . Allow the evaporator to defrost (Isola models
only). N.B.: do not use sharp or pointed metal objects to remove the ice from the evaporator. . Clean the
walls and accessories with a sponge dipped in water and sodium bicarbonate. Take care not to touch the
evaporator fins, which feature sharp edges. . Dry all parts with care and refit all components. Refit the
plug before turning on the appliance.