background image

Operator's guide:

1)Unpacking instructions
2)Opening the protective cover
3)Cleaning the internal basin
4)Cleaning the cover and external parts
5)Holders for containers and pastry shelves
6)Support shelves
7)Connection to the mains
8)Controls
9)Checking correct operation

10)Internal and evaporator cleaning

2)Replacement of the lamp
3)Access to the motor compartment
4)Replacement of the cover's lifting motor

Maintenance manual (Page 48):

1)Cleaning the condenser

5)Wiring diagram diagram of refrigeration unit

!

I

UK

D

E

F

NL

P

S

DK

FIN

B

GR

CZ

EE

LV

LT

H

M

PL

SK

SLO

6

Operator's guide

WARNINGS

It is most important that this instruction booklet is kept together with the appliance both for future
reference and for reasons of safety.
1

. Adults should operate this appliance only. Do not allow children to use the controls or play with it.

2

3

4

5

6

7

. It

is forbidden to modify in any way the main functions and characteristics of this appliance. . The electrical
installation of the appliance should be carried out by a qualified electrician or other competent person.

. Never attempt to carry out repairs unassisted. Inexpert repairs can cause serious damage and

malfunction. . Assistance has to be provided by an authorized engineer only. Always use original spare
parts. . This appliance is not suitable for the storage of basic commodities not including food-stuffs.

. The manufacturers of this appliance accept no responsibility for the consequences of misuse in

contravention of these safety instructions. It further reserves the right to carry out improvements without
prior notice.

8

9

10

11

12

13

. Avoid installing the cabinet directly in line with sunlight. . Nevere install the appliance near

sources of heat, such as radiators, stoves, etc.

. Keep the ventilation grills free from obstruction for at

least 30 cm.

.Ensure that the products displayed on the shelves and grills do not hang over the edges.

. If damp air or products to be refrigerated should cause ice to form on the evaporator, we recommend

stopping the compressor and placing the goods in special refrigerated containers, kept at the same
temperature, until defrosting is completed;if this is not carried out the compressor will continue to operate
leading to a wasteful consumption of electricity and poor performance.

. If the appliance is not working

and unused, it is indispensable to keep the door open at least 10 cm.

1. UNPACKING INSTRUCTIONS
CARDBOARD BOXES 1a.
WOODEN CRATE 1b.

2

3.

4.

5

6.

7

8

2. OPENING THE PROTECTIVE COVER
1.

2

3. CLEANING THE INTERNAL BASIN
1

2

3

4. CLEANING THE COVER AND EXTERNAL PARTS
1.

2

3

4

5. HOLDERS FOR CONTAINERS AND PASTRY SHELVES
1

2

3

4.

. 5.

6. SUPPORT SHELVES
M LUX version

Cut surrounding tape. Remove the cardboard package by sliding it upwards.

Remove the nails from the wooden crate with care. . Insert forks of forklift truck

between the appliance and pallet or crate.

Lift the appliance.

Remove the pallet or crate. . Place

the appliance on a flat, level surface.

Make sure there is nothing left in the package before disposing of

it. . Sort out the packaging materials in order to facilitate disposal. . The appliance can be locked in
place by engaging the wheel brakes (see fig. 1).

Plug the machine into the power supply socket, as described in Chapter 7.

. Turn the switch of the

electric lifting system (A) to position II until the cover is fully (see fig. 2).

. Remove the protection film from the stainless steel parts. . Clean the basin with a soft sponge and

neutral detergents. . Remove the plug on the rear side of the machine to drain any residual water.

Never use detergents containing alcohol or solvents which would irremediably damage the cover,

compromising its transparency. . Use only a soft damp sponge. . As far as the wooden surfaces are
concerned, use proprietary detergents especially designed for wooden surfaces, which are water-based
and do not contain solvents. . Dry with a clean cloth.

. Remove the protection film from the holders. . Place the longer holders in the slots provided on the

basin's rims. . Place the shorter holders in the slots provided in the longer holders. Different
arrangements are available for different container sizes and positions.

You can now put your containers

on the holders

For pastry models, you need only place the stainless steel shelves on the rims

(containers and stainless steel shelves are available upon demand) (see fig. 3).

: take hold of the bottom edge of the shelf and turn upwards (A) until the shelf is

horizontal. Push down the edge near to the basin (B) until the shelf is firmly secured in place (see fig. 4).

Summary of Contents for GOURMET 4 M

Page 1: ...The catering program Production code ISOLA 4 6 M M LUX GOURMET 4 6M M LUX Mod ISOLA 4 6 M M LUX GOURMET 4 6M M LUX 08 2005 ...

Page 2: ...ALLATIE EN GEBRUIK INSTALACE A POUŽITÍ UN INSTALACIJA IN UPORABA PAIGALDAMINE JA KASUTAMINE BEÉPÍTÉS ÉS HASZNÁLAT INŠTALÁCIA A POUŽITIE INSTALACJA I UZYTKOWANIE ISTALLAZJONI U UżU INSTALIAVIMAS IR NAUDOJIMAS MANUTENZIONE MAINTENANCE INSTANDHALTUNG MANTENIMIENTO ENTRETIEN ONDERHOUD MANUTENÇÃO UNDERHÅLL VEDLIGEHOLDEL SESANVISNING HUOLTO OHJEET ONDERHOUD ÚDRŽBA APKOPE VZDRŽEVANJE HOOLDUS KARBANTARTÁS...

Page 3: ...I UK D E F NL P S DK FIN B GR CZ EE LV LT H M PL SK SLO 2 Fig 2 Fig 1 Fig 4 Fig 3 2 4 3 T 0 I I I 12 5 P A 4 2 3 5 B A ...

Page 4: ...I UK D E F NL P S DK FIN B GR CZ EE LV LT H M PL SK SLO 3 Fig 6 A 1 6 5 7 12 5 P T 0 I I I 12 5 P 4 3 2 1 5 Fig 5 ...

Page 5: ...ried out the compressor will continue to operate leading to a wasteful consumption of electricity and poor performance If the appliance is not working and unused it is indispensable to keep the door open at least 10 cm 1 UNPACKING INSTRUCTIONS CARDBOARD BOXES 1a WOODEN CRATE 1b 2 3 4 5 6 7 8 2 OPENING THE PROTECTIVE COVER 1 2 3 CLEANING THE INTERNAL BASIN 1 2 3 4 CLEANING THE COVER AND EXTERNAL PA...

Page 6: ...ures controls situated in a protected panel on the front side to open and close the cover Position II to lift Position O to stop Position I to lower to switch on the internal lights to switch on the refrigeration unit to read the temperature in the counter to adjust the temperature setting a Press key to display the temperature set point which can be changed by pressing key or see fig 6 the plug i...

Page 7: ...ecken dürfen Sollte es durch die Luftfeuchtigkeit oder die zu kühlenden Produkte zu außergewöhnlicher Bildung von Eis auf dem Verdampfer kommen empfehlen wir den Kompressor auszuschalten und die Ware während des Abtauens bei gleicher Temperatur in dem vorgesehenen Behälter aufzubewahren andernfalls arbeitet der Kompressor ununterbrochen und verursacht einen unnötigen Energieverbrauch sowie niedrig...

Page 8: ...an das Stromnetz anschließen siehe Abb 5 Das Gerät ist mit Einstellsteuerungen ausgestattet die sich in einem geschützten Kasten auf der Vorderseite befinden Zum Öffnen und Schließen der Kuppel Position II Anhub Position O Stillstand Position I Absenkung Zum Einschalten der Innenbeleuchtung Zum Einschalten der Kühlanlage Gibt die Temperatur im Inneren des Geräts an Reguliert die Temperatur des Ger...

Page 9: ...EZA DE LA CAMPANA Y DEL EXTERIOR 1 2 3 4 5 DISTANCIADORES DE SOPORTE DE LAS CUBETAS Y PLANOS DE PASTELERÍA 1 2 3 4 5 Si se verificase una producción anómala de hielo en el evaporador causado bien por la humedad del aire o de los productos que se quieren refrigerar les aconsejamos que paren el compresor y que saquen y coloquen los alimentos en específicos contenedores refrigerados a la misma temper...

Page 10: ...es de conectarlo a la alimentación eléctrica Véase figura 5 El equipo consta de mandos de regulación situados en el cuadrante protegido situado en la parte delantera Sirve para abrir y cerrar la campana Posición elevación Posición parada Posición descenso Sirve para encender la luz interna Sirve para encender la instalación refrigeradora Indica la temperatura del equipo Regula la temperatura del e...

Page 11: ... élimination Il est possible de bloquer l appareil en agissant sur les roues avec frein voir illustration 1 Brancher la fiche au réseau électrique selon les indications du Chapitre 7 Appuyer sur l interrupteur de l élévateur électrique A en position II jusqu à l ouverture complète en fin de course voir illustration 2 Enlever la pellicule de protection de l acier inox Nettoyer la cuve avec une épon...

Page 12: ...ins 3 heures dans une position correcte avant de la mettre sous tension voir illustration 5 La vitrine est dotée de commandes de réglage situées sur un panneau avant protégé il sert à ouvrir et à fermer la vitrine bombée Position II pour lever Position O pour arrêter Position I pour abaisser il sert à allumer la lumière interne il sert à allumer le système de réfrigération il indique la températur...

Page 13: ...DRAGERS VAN DE BAKKEN EN DE PLATEN VOOR DE UITSTALLING VAN BANKETBAKKERIJPRODUCTEN 1 2 3 4 5 Bij abnormale ijsvorming op de verdamper die wordt veroorzaakt door de luchtvochtigheid of door de te koelen producten is het raadzaam de compressor uit te schakelen en de waren in een geschikte op dezelfde temperatuur gekoelde houder te plaatsen voor de tijd die nodig is voor het ontdooien als dit niet ge...

Page 14: ...per ongeluk verkeerd is neergezet dient u deze minstens 3 uur op de juiste stand te laten rusten alvorens deze op het elektriciteitsnet aan te sluiten zie Fig 5 De bedieningsknoppen van het apparaat zijn te vinden aan de voorkant op een afgeschermd paneel deze dient voor het openen en sluiten van de koepel Stand II om deze te openen Stand O voor de ruststand Stand I om deze te sluiten Deze dient o...

Page 15: ...I UK D E F NL P S DK FIN B GR CZ EE LV LT H M PL SK SLO 47 Fig 1 Fig 3 Fig 2 4 5 ...

Page 16: ... the lamp sockets in place Remove the lamp socket whilst holding the fluorescent tube and its protective cover Pull the protective cover out of the other lamp socket Replace the fluorescent tube Refit all components by following the above instructions in reverse order see fig 2 To access the motor compartment remove the ventilation grilles Lower the cover Turn the appliance off Remove the ventilat...

Page 17: ...her la douille en tenant le tube fluorescent et le tube transparent de protection Extraire le tube de protection de l autre douille Remplacer le tube fluorescent Réinstaller le tout en procédant en sens inverse voir illustration 2 Pour accéder au compartiment moteur il suffit de retirer les grilles d aération Tenir la vitrine bombée Couper la tension électrique Enlever les grilles d aération Dévis...

Page 18: ...I UK D E F NL P S DK FIN B GR CZ EE LV LT H M PL SK SLO 55 Isola 4 6 M M LUX Gourmet 4 6 M M LUX M M 9 6 11 3 10 14 13 16 1 8 12 15 ...

Page 19: ...I UK D E F NL P S DK FIN B GR CZ EE LV LT H M PL SK SLO 56 4 1 16 2 5 4 1 16 2 5 Gourmet Isola ...

Page 20: ...ampana Interruptor Evaporador Filtro Interruptor Caja de bornes Motorreductor Neon Reactor Sonda Enchufe Dispositivo de arranque Termostato Ventilador condensador 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 Compresseur Condenseur Commande vitrine bombée Interrupteur Évaporateur Filtre Interrupteur Bornier Motoréducteur Neon Réacteur Sonde Prise de courant Starter Thermostat Ventilateur condenseur 1 2 3 4...