![Dhollandia DH-VO.07.K9 Operation Manual Download Page 24](http://html1.mh-extra.com/html/dhollandia/dh-vo-07-k9/dh-vo-07-k9_operation-manual_2492160024.webp)
DHOLLANDIA
24
•
A fixed internal control should only be used inside the
vehicle body from a safe operator position that is a
minimum 16" x 16" square, clearly and permanently
marked at a minimum of 10" from the hazard zone
between the platform and the rear of the vehicle floor. A
fixed internal control should NEVER be used from a
position on the platform.
•
The marked operator positions on the platform must be
kept clear at all times. It is prohibited to place a load on
these dedicated areas.
•
In case of a main external control box with 2-hand operation, the power to any of the auxiliary controls must be connected to and
dependent upon the safety switch in the main external control box. Activation of the auxiliary controls must deactivate the functions
on the external control box.
•
It is prohibited to bypass or modify any of the safety features of the liftgate. If connection of the power to the external control box
does not deactivate external controls, stop using the liftgate, attach the 'WARNING. LIFTGATE OUT OF SERVICE. DO NOT
ATTEMPT TO OPERATE' sign provided with the liftgate, and contact an authorized DHOLLANDIA agent.
10”
16”
32”
•
When standing in front or behind the load, the operator risks being pushed off the platform, or being crushed between the
moving load and the rear frame of the vehicle body, resulting in serious bodily injury or death.
•
To prevent this hazard, ALWAYS stand on the side of the load, NEVER in front or behind.
Rest of page le intenonally blank.
Connued on next page.