Configuring MADI Redundancy
Slot 13 to 18 (and slot 34 to 39 in a 6 HU frame) can be operated in normal or redundant mode. If switched to redundant,
a MADI port duplicates the signals of the corresponding port on the left side of the router backplane.
Choose
Enabled
in the column
Redundancy
at the
DSP Frame I/O
to define the respective MADI port as redundant. If
the corresponding module on the left side fails, the redundant module on the right side will automatically take over.
Example
The MADI ports of slot 13 and 14 are switched to be redundant. Now they are carrying the same output signals as the
MADI ports of slot 3 and 4. They should be fed with redundant input signals of the MADI ports 3.1, 3.2, 4.1 and 4.2.
Toolbox5, DSP Frame I/O; The MADI ports of slot 13 and 14 are switched
to redundant.