Installation
System ID21
46
78438 7.0
5.6.2 COMPACT control unit
The COMPACT control unit can be equipped with a protective mechanism. A sensor unit (sensor
and processor) can be mounted under the tabletop between the table frames.
The sensor is attached to both the table frame and the tabletop. The contact point with the
tabletop is marked with a yellow dot, as shown in Figure 43.
Figure 43
Sensor unit
A
Sensor
B
Connecting cable (for connection to processor)
C
Connection for the sensor cable
D
Processor
E
Connecting cable for control unit
NOTICE
This protective mechanism only works when the sensor is correctly installed. Make sure that the
side of the sensor marked with a yellow dot is facing the tabletop.
CAUTION
•
You should only install and remove the sensor when it is completely disconnected from any
live current!
•
This safety mechanism is not effective unless the drilled holes are aligned exactly with each
other. Personal injury and property damage can result from improper alignment.
The screws are not included in our delivery.