background image

Installation

1. In the first time, add the device into the Z-Wave

TM

 network.  First,

make sure the primary controller is in the inclusion mode. And then

power on the device, just take out the insulation Mylar in the back side

of   the   device.   The   device   will   auto   start   the   NWI   (Network   Wide

Inclusion) mode. And it should be included in 5 seconds. You will see

the LED light ON one second.

2. Let the controller associate with the device into the first group, any

light switch that intend to be turned on when the device trig please

associate with the device into the second group.

After finish the test and decide to fix, then you can remove tape A, and

mounting the sensor by using tape B. The tamper key will pressed and

let the sensor enter normal mode.

Z-Wave Configuration Settings

Notice:

 

* All of the configuration, the data size is 1.
*   The   configuration   mark   with   star(*),   means   after   the   exclusion   the
setting still keep, don't reset to factory default. Unless the user execute the
“RESET” procedure.

8

Summary of Contents for MT 02648

Page 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Page 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Page 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Page 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Page 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Page 6: ...6...

Page 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Page 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Page 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Page 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Page 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Page 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Reviews: