background image

NO.

Name

Def.

Valid

A B C

Description

2 Basic Set 

Level

0xFF

All

  

Setting the BASIC command value to 
turn on the light. The 0xFF(-1) means 
turn on the light. For dimmer 
equipment 1 to 100 means the light 
strength.
0 means turn off the light.

3

(*)

PIR 

Sensitivity

80

0 ~

99

  

PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected 
long distance, but if there is more 
noise signal in the environment, it will 
re-trigger too frequency. 

4 Light 

Threshold

99

0 ~

100

  

Setting the illumination threshold to 
turn on the light. When the event 
triggered and the environment 
illumination lower then the threshold, 
the device will turn on the light.
0 means turn off illumination detected 
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination 
detected function. And always turn on 
the light.

Notice:

 In none test mode, only the 

value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.

NO.

Name

Def.

Valid

A B C

Description

NO.

Name

Def.

Valid

A B C

Description

5

(*)

Operation

Mode

0

All

Operation mode. Using bit to control.

0

  

Bit0

: Reserve.

0

  

Bit1

: 1 means enable test mode, 

        0 means disable normal mode.

Notice: 

This bit only effect by the DIP Switch 
setting to program mode.

0

  

Bit2

: Disable the door/window 

function.

0

  

Bit3

: Setting the temperature scale.

  0: 

Fahrenheit

, 1:

Celsius

0

  

Bit4

: Disable the illumination report 

after event triggered.

0

  

Bit5

: Disable the temperature report 

after event triggered.

0

  

Bit6

: Reserve.

0

  

Bit7: 

Disable the back key release 

into test mode.

NO.

Name

Def.

Valid

A B C

Description

9

Summary of Contents for MT 02648

Page 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Page 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Page 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Page 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Page 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Page 6: ...6...

Page 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Page 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Page 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Page 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Page 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Page 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Reviews: