background image

NO.

Name

Def.

Valid

A B C

Description

8

PIR Re-

Detect 

Interval 

Time

3

1 ~

127

  

In the normal mode, after the PIR 
motion detected, setting the re-detect 
time. 8 seconds per tick, default tick is 
3 (24 seconds).
Setting the suitable value to prevent 
received the trigger signal too 
frequency. Also can save the battery 
energy.

Notice:

 If this value bigger than the 

configuration setting

 

NO. 9. There is a 

period after the light turned off and 
the PIR not start detecting.

9

Turn Off 

Light 

Time

4

0 ~

127

  

After turn on the lighting, setting the 
delay time to turn off the lighting 
when the PIR motion is not detected. 
8 seconds per tick, default tick is 4 (32
seconds).
0 means never send turn off light 
command.

10

Auto 

Report 

Battery 

Time

12

0 ~

127

  

The interval time for auto report the 
battery level. 
0 means turn off auto report battery.
The default value is 12. The tick time 
can setting by the configuration No.20.

11

Auto Report
Door/Windo
w State 
Time

12

0 ~

127

  

The interval time for auto report the 
door/window state. 
0 means turn off auto report 
door/window state.
The default value is 12. The tick time 
can setting by the configuration No.20.

NO.

Name

Def.

Valid

A B C

Description

NO.

Name

Def.

Valid

A B C

Description

12

Auto Report
Illumination
Time

12

0 ~

127

  

The interval time for auto report the 
illumination. 
0 means turn off auto report 
illumination.
The default value is 12. The tick time 
can setting by the configuration No.20.

13

Auto Report
Temperatur
e Time

12

0 ~

127

  

The interval time for auto report the 
temperature. 
0 means turn off auto report 
temperature.
The default value is 12. The tick time 
can setting by the configuration No.20.

20

Auto Report
Tick 
Interval

30

0 ~

0xFF

  

The interval time for auto report each 
tick. Setting this configuration will 
effect configuration No.10, No.11, 
No.12 and No.13.

Caution

Setting to 

0

 means turn off 

all auto report function.

21

Temperature

 

Differential 
Report

1

0 ~

0x7F

  

The temperature differential to report.
0 means turn off this function. 
The unit is Fahrenheit.
Enable this function the device will 
detect every 

minutes

And when the temperature is over 140
degree Fahrenheit, it will continue 
report.
Enable this functionality will cause 
some issue please see the detail in the
“Temperature Report” section.

NO.

Name

Def.

Valid

A B C

Description

11

Summary of Contents for MT 02648

Page 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Page 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Page 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Page 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Page 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Page 6: ...6...

Page 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Page 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Page 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Page 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Page 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Page 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Reviews: