22

Illumination
Differential 
Report

0

0 ~

0x63

  

The illumination differential to report.
0 means turn off this function. 
The unit is percentage.
Enable this function the device will 
detect every 

minutes

Enable this functionality will cause 
some issue please see the detail in the
“Illumination Report” section.

NO.

Name

Def.

Valid

A B C

Description

Z-Wave Supported Command Class

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

COMMAND_CLASS_BATTERY

COMMAND_CLASS_NOTIFICATION_V4

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

COMMAND_CLASS_VERSION_V2

COMMAND_CLASS_SENSOR_BINARY_V2

COMMAND_CLASS_SENSOR_MULTILEVEL_V5

COMMAND_CLASS_WAKE_UP_V2

COMMAND_CLASS_ASSOCIATION_GRP_INFO

COMMAND_CLASS_POWERLEVEL

COMMAND_CLASS_DEVICE_RESET_LOCALLY

COMMAND_CLASS_MULTI_CMD

COMMAND_CLASS_SECURITY

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

COMMAND_CLASS_MARK

COMMAND_CLASS_BASIC

Specifications

Power by CR123A lithium battery.

Signal (Frequency):

868.40 MHz, 869.85 MHz(EU)

Range: 

Minimum 30 meters indoor, 

70 meters outdoor line of sight.

Operating Temperature: -10

o

C ~ 40

o

C

For indoor use only.

Specifications   subject   to   change   without   notice   due   to   continuing

product improvement.

 

Warning

Do not dispose of electrical appliances as unsorted municipal waste,

use   separate   collection   facilities.   Contact   your   local   government   for

information   regarding   the   collection   systems   available.   If   electrical

appliances are disposed of in landfills or dumps, hazardous substances

can leak into the groundwater and get into the food chain, damaging

your health and well-being.

When replacing old appliances with new once, the retailer is legally

obligated to take back your old appliance for disposal at least for free

of charge.

12

Summary of Contents for MT 02648

Page 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Page 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Page 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Page 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Page 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Page 6: ...6...

Page 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Page 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Page 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Page 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Page 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Page 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Reviews: