background image

Battery Installation

When   the   device   report   the   low   battery   message.   The   user   should

replace the battery to new one. The battery type is CR123A, 3.0V.

The way to open the front cover please follow below steps. 

1. Using a tool to press the 1-1 position, to release the cover.

2. Hold the front cover and pull back

3. Hold the front cover and pull up

Replace the new battery and install the cover back.

1. Put the front cover bottom to 1-1, and press down.

2. Push the front cover top to 2-1.

Choosing a Suitable Location

1. The recommended mounting height is 160cm

2. Don't let the device facing the window or the sunlight.

3. Don't let the device facing the source of heat. For instance the

heater or the air-condition.

7

Summary of Contents for MT 02648

Page 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Page 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Page 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Page 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Page 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Page 6: ...6...

Page 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Page 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Page 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Page 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Page 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Page 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Reviews: