AT commands: Detailed description
57
|
devolo MicroLink ISDN i
|
EN
052/131
Service not available at own or
remote connection or dialing of
an incorrect number
Check the dial number and the enabling
of the desired services (also applies to
PBX systems).
052/138
Own connection is busy.
Connection is in use by other terminal
devices. End existing connection if nec-
essary.
052/144
Semi-permanent connection
(SPC) not supported by network
SPC must be requested from network
operator.
052/145
Requested service not available
Service must be requested from network
operator.
052/160
Outgoing connection blocked
Have blockage removed by network
operator.
052/161
Remote station busy
Dial again later.
052/165
Semi-permanent connection
(SPC) not permitted between
these subscribers
SPC must be requested from network
operator.
052/181
Target number, service or serv-
ice characteristic incorrect
Check the dial number and the enabling
of the desired services (also applies to
PBX systems).
052/184
Target dial number has changed
Obtain new number from the remote
station.
052/185
From remote terminal unit: Not
operational
Check the operational readiness of the
remote station.
052/186
Remote terminal unit does not
answer
Check the operational readiness of the
remote station and the terminal selec-
tion digit of the dial number.
052/187
Message from remote terminal
unit: Unit busy
Dial again later.
052/189
Target subscriber: Blocked
against incoming connections
Check with remote station regarding
blockage.
052/190
Target subscriber rejected con-
nection
Check with remote station.
052/217
Network bottleneck (e.g. con-
gestion)
Dial again later.
Error
codes
S154/S155
Description
Cause and possible correction
Summary of Contents for MicroLlink
Page 1: ...MicroLink ISDN i...