AT commands: Detailed description
55
|
devolo MicroLink ISDN i
|
EN
Incoming call – RI = Ring Indicator
This MicroLink ISDN i output becomes active (ON) when the adapter detects
an incoming call (see also command
ATA
). Incoming calls are detected only
if the DTR control line is active (ON) or the command
AT&D0
has been
issued.
Connection – DCD = Data Carrier Detect
This MicroLink ISDN i output normally becomes active (ON) when the adapter
has established a valid connection.
3.4
Error messages
In the event of errors, the contents of the registers S154 and S155 return error
codes which may be used to localize the problem. These registers can be
read using the commands
ATS154?
or
ATS155?
.
Error
codes
S154/S155
Description
Cause and possible correction
AT-level error group
001/001
Establishment of connection
aborted by character input dur-
ing establishment
Input of characters during establishment
of connection not permitted. If the input
of characters is to be permitted during
call establishment, bit 6 must be set in
register S14 (polling enabled during
establishment of connection).
001/003
Call not (no longer) present
(with
ATA
or
ATO
)
Opposite station has hung up or another
unit has answered the call.
001/004
Internet service provider proto-
col error at the serial port
Reestablish the connection.
001/005
Connection aborted by
ATZ
The command
ATZ
in the command
phase causes the abort of an existing
connection.
001/006
Inactivity timer elapsed (con-
nection aborted)
No more data was transmitted during
the time period specified in register S30
or by the
AT\Tn
command.
001/007
Establishment of connection
aborted by DTR = off
The DTR signal was deactivated, e.g. by
the terminal program.
001/009
Establishment of connection
aborted by
ATH
Establishment of connection canceled.
Summary of Contents for MicroLlink