en - 11
A-306-1
Ac Adapter and Power cord/dc Adapter
The adapters and power cords should be cleaned as needed. To clean, follow these steps:
1. Disconnect cords from the iGo before cleaning.
2. Clean the cords by using a damp cloth with a mild household cleaner and wipe dry.
cannula and tubing
Clean and replace the cannula and tubing as instructed by your DeVilbiss provider.
exterior covers and deVilbiss rechargeable battery
WArnInG
To avoid electric shock, do not remove the iGo covers. The covers should only be removed by a qualified DeVilbiss provider. Do not apply liquid directly to the
covers or utilize any petroleum-based solvents or cleaning agents.
Use of harsh chemicals (including alcohol) is not recommended. If bactericidal cleaning is required, a non-alcohol based product should be used to avoid
inadvertent damage.
The exterior covers and rechargeable battery should be cleaned as needed. To clean, follow these steps:
1. The battery should remain installed and be wiped clean with the covers. If battery is removed, wipe the battery bay and battery with a Dry Cloth only.
2. Clean the iGo exterior covers by using a damp cloth with a mild household cleaner and wipe it dry.
humidifier (reusable bottle)
If your physician has prescribed humidification for use during continuous flow mode, clean your humidifier bottle daily. Follow the instructions supplied by the manufacturer. If
no cleaning instructions were supplied, follow these steps:
1. Wash the humidifier in a solution of hot water and dishwashing detergent.
2. Soak the humidifier in a solution of one part white vinegar to three parts hot water for 30 minutes. This solution acts as a germicidal agent.
3. Rinse thoroughly with hot tap water and refill with distilled water for use. Do not overfill.
rolling carry case and detachable Wheeled cart
The carry case and/or cart should be cleaned as needed. To clean, follow these steps:
1. Remove the iGo from the carry case or cart before cleaning.
2. Clean the case or cart by using a damp cloth with a mild household cleaner and wipe dry.
battery Storage
Your Battery should be stored in a cool, dry location when not in use.
battery disposal / disposal of equipment and Accessories
Your Battery is rechargeable and can be recycled. Follow local governing ordinances and recycling plans regarding disposal of device components. Do not dispose of the
rechargeable Battery. Contact your DeVilbiss provider before disposal of battery or any iGo components.
SPecIFIcAtIonS
Dimensions (H x W x D) ...........................................................................................................................................15 inches x 11 inches x 8 inches (38.0 cm x 28.0 cm x 20.0 cm)
Weight ..........................................................................................................................................................................................................................19 pounds (8.6 kg) with Battery
15.5 pounds (7.0 kg) without Battery
Flow Rate Settings ................................................................................................................................................................................................................1 to 6 in PulseDose Mode
1 to 3 LPM in Continuous Flow Mode
Maximum Recommended Continuous Flow (@ nominal outlet pressures of 0 and 7 kPa) ................................................................................................................................3 LPM
Maximum Breathing Rate (PulseDose mode only) ...................................................................................................................................................................40 BPM @ settings 1-4
37 BPM @ setting 5
31 BPM @ setting 6
Oxygen Concentration ................................................................................................................................................................................................... 91% ± 3% for all flow settings
Maximum System Pressure ............................................................................................................................................................................................................15 psig (103.5 kPa)
Oxygen Outlet Pressure ...................................................................................................................................................................................................5.0 ± 1.0 psig (34.5 ± 7 kPa)
Operating Temperature.....................................................................................................................................................................................................41°F to 104°F (5°C to 40°C)
Operating Humidity ...........................................................................................................................................................................................10% - 95% at 82.4°F (28°C) dew point
Transportation and Storage Temperature ................................................................................................................................................................ -4°F to +140°F (-20°C to +60°C)
Transportation and Storage Humidity ..............................................................................................................................................................................
10% to 95% non-condensing
Transportation and Storage Atmospheric Pressure (at nominal temperature and humidity) (Tested at ~933 hPa) ......................................................................640 hPA - 1010 hPA
Altitude (Tested at ~933 hPa) ................................................................................................................................................................................... 0 –13,123 feet (0 – 4,000 meters)
Nominal Sound Level ....................................................................................................................................................................................40 dBA at 3 in PulseDose Delivery Mode
Maximum Sound Level in Battery Mode (from front) @ 3 LPM continuous flow ................................................................................................................................................48
dBA
Maximum Sound Level as test per ISO 8359 .....................................................................................................................................................................................................55 dBA
Pressure Relief Mechanism .......................................................................................................................................................................................... 20 psi ±20% (138 kPa ± 20%)
OSD Set Points ...............................................................................................................................................................................................................≥ 84% - Normal Light (green)
75-85% - Low O
2
Light (yellow)
< 75% - Service Required Light (red) and Audible Alert
electrical Power:
DeVilbiss Rechargeable Battery (Lithium Ion) ...................................................................................................................................................................................... 8.8 Amp Hrs
AC Adapter Input Voltage Range ......................................................................................................................................................................................... 100-250Vac, 50/60 Hz
DC Adapter ......................................................................................................................................................................................................... 12 Volt Negative Ground Vehicles