ElectroVap®
ELMC-SB
37
5.4
MAINTENANCE ALERTS
M4:
CONTACTOR TO
REPLACE
After 10,000 hours of operation, it is recommended to
replace the contactor.
The unit is not stopped
M3:
MAINTENANCE
NOT DONE: PURGE
This message appears if 100 hours elapsed between the
appearance of the M2 and M3 message and no
maintenance has been done.
Then the unit is shut down and follows the procedure:
1.
1. Emptying the cylinder
2.
2. Cooling the cylinder
3.
3. Ready for maintenance
M2:
MAINTENANCE
TO DO
The maintenance timer has arrived at 0, it is necessary to
do the maintenance of the device. The unit is not stopped
M1:
50 HOURS
CONTROL
This message will appear 50 Hrs
after the first start.
It is then necessary to check the correct tightening of
electrical and hydraulic connections (steam pipe, drain
system, water supply...). The unit is not stopped
TO CARRY OUT A RESET FOR THE ABOVE
MESSAGES, FOLLOW THIS PROCEDURE:
-Switch the unit to drain by pressing the manual drain button (4).
-Press button 3 for at least 5 seconds.
5
1
2
3
4
Summary of Contents for ElectroVap ELMC 20-30 SB
Page 1: ...STEAM GENERATOR FOR STEAM ROOM ElectroVap ELMC SB Series Instruction Operation Manual ...
Page 25: ...ElectroVap ELMC SB 25 3 8 6 Wiring diagrams ELMC 5 to 10 Up V 1x200 240V 50 60Hz ...
Page 26: ...ElectroVap ELMC SB 26 ELMC 5 to 30 Up V 3x200 690V 50 60Hz ...
Page 27: ...ElectroVap ELMC SB 27 ELMC 40 to 60 Up V 3x200 690V 50 60Hz ...
Page 28: ...ElectroVap ELMC SB 28 ELMC 90 Up V 3x200 690V 50 60Hz ...
Page 29: ...ElectroVap ELMC SB 29 3 9 OPTION Transformer connection ...
Page 51: ...ElectroVap ELMC SB 51 ...