ElectroVap®
ELMC-SB
14
3.5
DRAIN HOSE CONNECTION
The following drawing shows the connection of the drain hose that must be made.
Use a Ø 25 mm rubber drain hose with the supplied hose clamp, heat resistant (up to 100°C).
Connect the hose to the drain system. It is recommended to replace it regularly.
If you use a rigid pipe, it must be made of heat-resistant PVC (up to 100°C).
The drain hose must be free of any obstacles.
It is recommended that each generator has its own drain hose.
If possible, use a water trap with a cover (see picture below).
Hose minimum Ø 60 mm (option)
Collecting water tank (option)
Drain hose (option)
α
Fig. A 3-5.
Example of an installation with a collecting water tank.
Keep a minimum pitch (
α)
of 10° for both the draining hose of the generator and for general drain pipe
(see picture).
Collecting water
tank (option)
Drain hose
(option)
To sewer
pipe
d
Drainage water
The drain hose should extend approximately 8 cm (d) into the sump. (The hose must never be in contact
with the waste water in the tank)