Accessories - Electronic Autodrain
Maximum working pressure of 230 psi (16 Bar).
Includes Manual Ball Valve and Filter
Drain duration of between .05 to 10 seconds
Operating cycle time of 1 to 45 minutes
UL and CSA approved
Wire Mesh
Filter
Moisture
from Tank
1.
Maintenance/service work must only be done when
the Autodrain is not under pressure.
2.
Ensure the Autodrain is not subjected to
temperatures below freezing.
3.
Suitable arrangements must be made to ensure the
moisture is properly contained once evacuated from
the AutoDrain.
The ‘KK-9840’ Autodrain is designed to drain moisture from the Compressor Unit based on an internal
Timer. The Timer is an electrical device, requires 120-60-1 to operate, and can therefore be plugged
into any wall outlet. A six foot (1.8 m) power cord is supplied.
The Autodrain is equipped with a Ball Valve, this allowing the air/moisture supply to the Drain to be
closed. The Ball Valve is also coupled with an internal wire mesh Filter, this to clean any impurities from
the air/moisture and prevent them from clogging the Autodrain mechanism.
By simply adjusting the two dials on the Autodrain Timer, the duration of the drains and the time
between drains can be altered to suit your particular application. The duration for the drain can be set
between 0.5 to 10 seconds, the time between drains 1 to 45 minutes.
As noted, suitable arrangements must be made to contain the condensate that is expelled from the
Autodrain. As the condensate may contain traces of oil, it must be disposed of accordingly.
What is the purpose of the ‘KK-9840’ Autodrain?
Specifications:
Important Information:
Maintenance:
The Wire Mesh Filter as shown above must be cleaned
periodically in order to ensure that the Unit works
properly, and does so for a long period of time.
De-pressurize the Unit, remove the End Cap, and remove
the Wire Mesh Filter. Clean with water, and replace.
Ball Valve
End Cap
Timer
- 14 -
HDI-01
Mar ‘07