![Devair HDI-01 Installation Maintenance And Service Manual Download Page 10](http://html.mh-extra.com/html/devair/hdi-01/hdi-01_installation-maintenance-and-service-manual_2488565010.webp)
Fill the Crankcase to the lowest thread at the Oil
Fill Port Opening.
Do not under or
overfill.
See drawing below.
Always replace the O-Ring when filling, and
tightly screw in Oil Fill Plug using a crescent
w r e n c h . U s e o n l y
D e v a i r P r e m i u m
Compressor Oil
for the Air Compressor, as it
has been specially formulated for your Unit, and
contains only two additives, a rust inhibitor and
an anti foaming agent.
The following Maintenance Kits are available
through your Devair Distributor, the Kits
including Devair Premium Oil and Air Filter (s).
Do not attempt to operate the Unit without
first checking whether there is Oil in the
Pump. Add Oil as required. Serious
damage may result from use, however
limited, without Oil.
Use of improper Oil may negatively a f f e c t
Compressor Pump performance or
shorten Pump life. Resulting problems are
not covered by the Devair Inc. Air
Compressor Warranty.
Pump Lubrication
- 10 -
Devair Premium
Mineral Oils
Devair Pump Model
Devair Pump Model
Devair Premium Synthetic Oil
(used in
high heat or high duty applications or
when Beltguard Aftercoolers are used)
DV Lube20 (20 Wgt)
Part No. ‘PR20’
DV Lube30 (30 Wgt)
Part No. ‘PR30’
123
247
44642
OJ-2000 (20 Weight)
223
447
247
447
Up to 90°F (32°C)
MK-223
MKS-247
MK-247
90°F + (32°C +)
MK-223
MKS-447
MK-247
MK-447
Room (Ambient)
Temperature
Kit Part Number
Kit Part Number
'O' Ring
Proper Oil Level
(to bottom thread of Oil Port)
Oil Filler
Plug
Section Through CrankCase
at Oil Fill Port
Kits c/w Mineral Oil (20 Weight only)
Kits c/w Synthetic Oil
HDI-01
Mar ‘07
Distributed by: CENTRAIR Air Systems & Supplies, 68 Hooper Rd., Unit 5, Barrie, ON L4N 8Z9
Phone: 705-722-5747 Fax: 705-722-5458 [email protected] www.centrair.ca
All manuals and user guides at all-guides.com