background image

11 

Table 3 

Parts list 

 

 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03996

ELECTRICAL PANEL

Panel only

2

B04004

EXIT/ENTRIES PLATE INSUL ATION

3

L07F016

SWITCH

4

L01J001

BREAKER

5

B03998

END PLATE

6

B03995

JACKET

7

B03994

CABINET

8

B04003

INSULATION CONTOUR

9A

L99H013

ELEMENT 3KW

9B

L99H014

ELEMENT 4KW

9C

L99H015

ELEMENT 5KW

9D

L99H016

ELEMENT 6KW

10

B03970

SEALING GASKET ELEMENT

11

R02J012

WELL 3/8" NPT

12

R02J001

WELL 1/2" NPT

13

G06F006

PLUG 1/4"NPT

14

B03977-01

BOILER ASSEMBLY (1 ELEMENT)

Boiler only

14

B03977-02

BOILER ASSEMBLY (2 ELEMENTS)

Boiler only

15

R02L006

TRIDICATOR 1/4"NPT

16

B03984-01

COVER ASSEMBLY

Cover, cosmetic and wiring diagram included

17

B04000-02

TERMINAL  (2X6 POS ITIONS)

18

R02F016

AQUASTAT

Adjustment hi-limi t temperature

19

R99G006

RECTIFIER CONTROL

20

L01H030

RELAY SPDT 22VDC

21

B04002

ELECTRICAL KIT

22

A20009-04

BLACK WIRE ELEMENT

23

A20009-05

RED WIRE ELEMENT

24

L01H009

RELAY SPDT 24VAC

25

R99G007

RECTIFIER /TEMPORISATOR CONTROL

26

R02F017

AQUASTAT

Adjustment temperature control

27

L01F010

TRANSFORMER 208/240/24

28

L99F005

TERMINAL  BLOCK

29

G11F012

RELIEF VALVE 3/4 "

30

G11Z002

DRAIN FAUCET 3/4"

Summary of Contents for HYDRA COMPACT HYDRAC03-M2401M

Page 1: ...ontr les Appeler un technicien qualifi INSTALLATEUR TECHNICIEN Utiliser les renseignements dans ce manuel pour l installation et l entretien de l appareil et garder le document pr s de l unit pour r f...

Page 2: ...ipement doivent tre adress es l entreprise o l achat fut effectu Lorsque toutes les tapes d installation auront t compl t es remettre ce manuel dans son enveloppe originale et la conserver pr s de la...

Page 3: ...r voir une porte ou un panneau d montable en fa ade pour l acc s au panneau contr le 1 6 SYST ME DE DISTRIBUTION Le bon fonctionnement de votre syst me de chauffage d pend directement de la qualit d i...

Page 4: ...re et l alimentation d eau du b timent b 1 r servoir d expansion pr pressuris 12 lb po2 de dimension appropri e c 1 ou des purgeurs d air automatique d 1 ou des pompes circulatoires de capacit ad qua...

Page 5: ...u Le dimensionnement des conducteurs doit tre fait en respect de la derni re dition des codes locaux ou nationaux Ne pas se conformer cette r gle pourrait entra ner des dommages corporels la mort et o...

Page 6: ...urer que la temp rature ambiante o est install l appareil ne d passe pas 27 C 80 F AVERTISSEMENT La n gligence de faire r parer une fuite du syst me le fait d utiliser la chaudi re comme source d appr...

Page 7: ...exp dition 2 25 3 3 9 4 12 5 12 15 6 0 81 1 08 3 4 4 12 5 16 7 15 6 20 9 1 08 1 44 3 75 5 5 15 6 20 8 19 5 26 1 35 1 81 4 5 6 3 3 18 8 25 0 23 5 31 3 1 63 2 17 5 25 7 4 3 21 9 29 2 27 4 36 5 1 90 2 5...

Page 8: ...8 Figure 4 Sch ma type d une installation une zone Figure 5 Diagramme multizone avec plus d un circulateur...

Page 9: ...9 Figure 6 Diagramme multizone avec valves motoris es Figure 7 Diagramme lectrique...

Page 10: ...10 SECTION 6 PI CES DE REMPLACEMENT Figure 8 Vue explos e...

Page 11: ...RE 1 ELEMENT Chaudi re seulement 14 B03977 02 ASS CHAUDI RE 2 ELEMENTS Chaudi re seulement 15 R02L006 THERMOMANOMETRE 1 4 NPT 16 B03984 01 ASS COUVERCLE Comprend couvercle cosmetique et diagramme lect...

Page 12: ......

Page 13: ...ner s Manual Dettson Industries Inc Manufactured by 3400 Industrial Boulevard Sherbrooke Qc Canada J1L 1V8 Attention Do not tamper with the unit or its controls Call a qualified service technician Pri...

Page 14: ...y where the equipment was purchased Upon completion of the installation this manual should be placed back into its original envelope and kept near the boiler for future reference 1 3 DELIVERY Upon del...

Page 15: ...an enclosure provide a door or a removable panel in front to access the control panel 1 6 DISTRIBUTION SYSTEM The proper functioning of your heating system is directly related to the quality of the pl...

Page 16: ...n water supply in the building b 1 expansion tank pre pressurized to 12 psi and of appropriate size c 1 or more automatic air purge valves d 1 or more circulating pumps of appropriate capacity CAUTION...

Page 17: ...hen using 208V change the connector s position at the primary of the transformer Refer to the boiler nameplate and the technical specifications in this manual to select the proper breaker and wire siz...

Page 18: ...nit is installed does not exceed 27o C 80o F CAUTION The boiler guaranty may be invalidated if water leaks in the system are not repaired the boiler is used as a source of domestic hot water or a sign...

Page 19: ...5 3 3 9 4 12 5 12 15 6 0 81 1 08 3 4 4 12 5 16 7 15 6 20 9 1 08 1 44 3 75 5 5 15 6 20 8 19 5 26 1 35 1 81 4 5 6 3 3 18 8 25 0 23 5 31 3 1 63 2 17 5 25 7 4 3 21 9 29 2 27 4 36 5 1 90 2 53 6 8 4 4 25 33...

Page 20: ...8 Figure 4 Typical Diagram of a Single Zone Installation Figure 5 Multizone Diagram with more than one Circulator...

Page 21: ...9 Figure 6 Multizone diagram with Motorized Valves Figure 7 Electrical Diagram...

Page 22: ...10 SECTION 6 REMPLACEMENT PARTS Figure 8 Exploded Vue...

Page 23: ...LER ASSEMBLY 1 ELEMENT Boiler only 14 B03977 02 BOILER ASSEMBLY 2 ELEMENTS Boiler only 15 R02L006 TRIDICATOR 1 4 NPT 16 B03984 01 COVER ASSEMBLY Cover cosmetic and wiring diagram included 17 B04000 02...

Page 24: ......

Reviews: