background image

SECTION 5 

TECHNICAL DATA 

 
 

Table 2 

Hydra Compact – Technical specifications 

 

 P

O

W

E

R

 (

k

W

@

2

0

8

V

)

 P

O

W

E

R

 (

k

W

@

2

4

0

V

)

 V

o

lt

s

 -

 H

e

rt

z

 -

 P

h

a

s

e

 E

le

c

tr

ic

 e

le

m

e

n

#

1

 (

K

w

)

 E

le

c

tr

ic

 e

le

m

e

n

#

2

 (

K

w

)

 C

o

n

s

u

m

p

ti

o

n

 (

A

m

p

)

  

C

ir

c

u

it

 A

m

p

e

ra

g

e

 (

w

ir

e

 s

iz

in

g

)

 G

E

N

E

R

A

L

 I

N

F

O

R

M

A

T

IO

N

S

 S

u

p

p

ly

 -

 R

e

tu

rn

 M

in

im

u

m

 w

a

te

fl

o

w

 U

S

G

/m

in

 O

v

e

ra

ll 

D

im

e

n

s

io

n

s

 (

w

id

h

x

 d

e

e

p

 x

 h

ig

h

t)

 S

h

ip

p

in

g

 w

e

ig

h

t

2.25

3

3

-

9.4 / 12.5

12 / 15.6

0.81 / 1.08

3

4

4

-

12.5 / 16.7

15.6 / 20.9

1.08 / 1.44

3.75

5

5

-

15.6 / 20.8

19.5 / 26

1.35 / 1.81

4.5

6

3

3

18.8 / 25.0

23.5 / 31.3

1.63 / 2.17

5.25

7

4

3

21.9 / 29.2

27.4 / 36.5

1.90 / 2.53

6

8

4

4

25 / 33.3

31.3 / 41.6

2.17 / 2.89

6.75

9

5

4

28.2 / 37.5

35.3 / 46.9

2.44 / 3.25

7.5

10

5

5

31.3 / 41.7

39.1 / 52.1

2.71 / 3.61

8.25

11

6

5

34.4 / 45.8

43 / 57.3

2.98 / 3.97

9

12

6

6

37.6 / 50.0

47 / 62.5

3.25 / 4.33

4

4

 l

b

 (

2

0

 k

g

)

In all cases, refer to applicable local and national codes.

2

0

8

 /

 2

4

0

 -

 6

0

 -

 1

1

'' 

N

P

T

 f

e

m

a

le

8

 3

/1

6

'' 

X

 8

 7

/1

6

'' 

X

 2

1

 3

/4

''

 

 

Figure 3 : Boiler Dimensions 

 

Summary of Contents for HYDRA COMPACT HYDRAC03-M2401M

Page 1: ...ontr les Appeler un technicien qualifi INSTALLATEUR TECHNICIEN Utiliser les renseignements dans ce manuel pour l installation et l entretien de l appareil et garder le document pr s de l unit pour r f...

Page 2: ...ipement doivent tre adress es l entreprise o l achat fut effectu Lorsque toutes les tapes d installation auront t compl t es remettre ce manuel dans son enveloppe originale et la conserver pr s de la...

Page 3: ...r voir une porte ou un panneau d montable en fa ade pour l acc s au panneau contr le 1 6 SYST ME DE DISTRIBUTION Le bon fonctionnement de votre syst me de chauffage d pend directement de la qualit d i...

Page 4: ...re et l alimentation d eau du b timent b 1 r servoir d expansion pr pressuris 12 lb po2 de dimension appropri e c 1 ou des purgeurs d air automatique d 1 ou des pompes circulatoires de capacit ad qua...

Page 5: ...u Le dimensionnement des conducteurs doit tre fait en respect de la derni re dition des codes locaux ou nationaux Ne pas se conformer cette r gle pourrait entra ner des dommages corporels la mort et o...

Page 6: ...urer que la temp rature ambiante o est install l appareil ne d passe pas 27 C 80 F AVERTISSEMENT La n gligence de faire r parer une fuite du syst me le fait d utiliser la chaudi re comme source d appr...

Page 7: ...exp dition 2 25 3 3 9 4 12 5 12 15 6 0 81 1 08 3 4 4 12 5 16 7 15 6 20 9 1 08 1 44 3 75 5 5 15 6 20 8 19 5 26 1 35 1 81 4 5 6 3 3 18 8 25 0 23 5 31 3 1 63 2 17 5 25 7 4 3 21 9 29 2 27 4 36 5 1 90 2 5...

Page 8: ...8 Figure 4 Sch ma type d une installation une zone Figure 5 Diagramme multizone avec plus d un circulateur...

Page 9: ...9 Figure 6 Diagramme multizone avec valves motoris es Figure 7 Diagramme lectrique...

Page 10: ...10 SECTION 6 PI CES DE REMPLACEMENT Figure 8 Vue explos e...

Page 11: ...RE 1 ELEMENT Chaudi re seulement 14 B03977 02 ASS CHAUDI RE 2 ELEMENTS Chaudi re seulement 15 R02L006 THERMOMANOMETRE 1 4 NPT 16 B03984 01 ASS COUVERCLE Comprend couvercle cosmetique et diagramme lect...

Page 12: ......

Page 13: ...ner s Manual Dettson Industries Inc Manufactured by 3400 Industrial Boulevard Sherbrooke Qc Canada J1L 1V8 Attention Do not tamper with the unit or its controls Call a qualified service technician Pri...

Page 14: ...y where the equipment was purchased Upon completion of the installation this manual should be placed back into its original envelope and kept near the boiler for future reference 1 3 DELIVERY Upon del...

Page 15: ...an enclosure provide a door or a removable panel in front to access the control panel 1 6 DISTRIBUTION SYSTEM The proper functioning of your heating system is directly related to the quality of the pl...

Page 16: ...n water supply in the building b 1 expansion tank pre pressurized to 12 psi and of appropriate size c 1 or more automatic air purge valves d 1 or more circulating pumps of appropriate capacity CAUTION...

Page 17: ...hen using 208V change the connector s position at the primary of the transformer Refer to the boiler nameplate and the technical specifications in this manual to select the proper breaker and wire siz...

Page 18: ...nit is installed does not exceed 27o C 80o F CAUTION The boiler guaranty may be invalidated if water leaks in the system are not repaired the boiler is used as a source of domestic hot water or a sign...

Page 19: ...5 3 3 9 4 12 5 12 15 6 0 81 1 08 3 4 4 12 5 16 7 15 6 20 9 1 08 1 44 3 75 5 5 15 6 20 8 19 5 26 1 35 1 81 4 5 6 3 3 18 8 25 0 23 5 31 3 1 63 2 17 5 25 7 4 3 21 9 29 2 27 4 36 5 1 90 2 53 6 8 4 4 25 33...

Page 20: ...8 Figure 4 Typical Diagram of a Single Zone Installation Figure 5 Multizone Diagram with more than one Circulator...

Page 21: ...9 Figure 6 Multizone diagram with Motorized Valves Figure 7 Electrical Diagram...

Page 22: ...10 SECTION 6 REMPLACEMENT PARTS Figure 8 Exploded Vue...

Page 23: ...LER ASSEMBLY 1 ELEMENT Boiler only 14 B03977 02 BOILER ASSEMBLY 2 ELEMENTS Boiler only 15 R02L006 TRIDICATOR 1 4 NPT 16 B03984 01 COVER ASSEMBLY Cover cosmetic and wiring diagram included 17 B04000 02...

Page 24: ......

Reviews: