SECTION 1 

INSTALLATION 

 

 
1.1) 

DANGER, WARNING AND CAUTION

 

 
The  words  DANGER, WARNING and  CAUTION  are  used  to  identify 
the  levels  of  seriousness  of  certain  hazards.  It  is  important  that  you 
understand their meaning. You will notice these words in the manual 
as follows: 
 

DANGER 

Immediate  hazards  which  WILL  result  in  death  or 
serious injury. 

 
 

WARNING 

 

Hazards or unsafe practices which CAN result 
in death or injury. 

 
 

CAUTION 

Hazards or unsafe practices which CAN result in 
personal injury, product or property damage. 

 
 

1.2) 

HEATING WITH HOT WATER 

 
Your  HYDRA  COMPACT  electric  boiler  was  carefully  assembled 
and checked in our plant, so that it will deliver warmth and comfort to 
your home for many years to come. 
 
This manual is intended to provide the necessary information for the 
installation  of  the  unit,  how  it  functions  and  explains  security 
measures which are particular to this type of equipment. 
 
It  is  essential  that  the  persons  installing,  operating  or  adjusting  the 
boiler  carefully  read  this manual, in  order  to  completely  understand 
and be familiar with the procedures to be followed. 
 
Any  questions  relative  to  the  operation,  maintenance  or  guarantee 
should  be  directed  to  the  company  where  the  equipment  was 
purchased.  
 
Upon  completion  of  the  installation,  this  manual  should  be  placed 
back  into  its  original  envelope  and  kept  near  the  boiler  for  future 
reference. 

 

 

1.3) 

DELIVERY 

 
Upon delivery of the boiler, check the nameplate to be sure that 
you have received the model with the correct rating and proper 
voltage. 
 
The following items are supplied with the unit: 

A pressure relief valve, adjusted to 30 psi; 

A drain valve; 

A  ¼‘’  plug  to  cork  the  ¼’’  tapped  hole  between  the 
elements  in  the  case  the  boiler  is  installed  in  any 
other position than upside. 

 

1.4) 

INSTALLATION 

 

WARNING 

 

The installation of this unit must be performed 
by  a  qualified  technician  and  it  must  conform 
to  the  standards  and  regulations  in  force  as 
well  as  the  Canadian  Installation  Code  for 
Hydronic Heating Systems CSA B214-01. 

 

 

1.4.1)  Positioning 

 

The  unit  must  be  installed  in  an  area  that  is  dry,  non-corrosive, 
without  excessive  dust,  well  ventilated  and  where  the  ambient 
temperature does not exceed 27

o

C (80

o

F). 

 

The boiler can be installed directly on a wall with 4 screws. 2 screws 
in the elements compartment and 2 screws on each side of the unit. 
Ensure  that  the  unit  is  well  fixed  on  the  wall  utilizing  the  4 
points of fixation.
  
 
The boiler can be installed in 8 possible configurations as shown in 
figure 1. 
 
Ensure  that  it  is  installed  level  and  that  the  clearances  indicated  in 
Table 1 are respected. 

 

 

Summary of Contents for HYDRA COMPACT HYDRAC03-M2401M

Page 1: ...ontr les Appeler un technicien qualifi INSTALLATEUR TECHNICIEN Utiliser les renseignements dans ce manuel pour l installation et l entretien de l appareil et garder le document pr s de l unit pour r f...

Page 2: ...ipement doivent tre adress es l entreprise o l achat fut effectu Lorsque toutes les tapes d installation auront t compl t es remettre ce manuel dans son enveloppe originale et la conserver pr s de la...

Page 3: ...r voir une porte ou un panneau d montable en fa ade pour l acc s au panneau contr le 1 6 SYST ME DE DISTRIBUTION Le bon fonctionnement de votre syst me de chauffage d pend directement de la qualit d i...

Page 4: ...re et l alimentation d eau du b timent b 1 r servoir d expansion pr pressuris 12 lb po2 de dimension appropri e c 1 ou des purgeurs d air automatique d 1 ou des pompes circulatoires de capacit ad qua...

Page 5: ...u Le dimensionnement des conducteurs doit tre fait en respect de la derni re dition des codes locaux ou nationaux Ne pas se conformer cette r gle pourrait entra ner des dommages corporels la mort et o...

Page 6: ...urer que la temp rature ambiante o est install l appareil ne d passe pas 27 C 80 F AVERTISSEMENT La n gligence de faire r parer une fuite du syst me le fait d utiliser la chaudi re comme source d appr...

Page 7: ...exp dition 2 25 3 3 9 4 12 5 12 15 6 0 81 1 08 3 4 4 12 5 16 7 15 6 20 9 1 08 1 44 3 75 5 5 15 6 20 8 19 5 26 1 35 1 81 4 5 6 3 3 18 8 25 0 23 5 31 3 1 63 2 17 5 25 7 4 3 21 9 29 2 27 4 36 5 1 90 2 5...

Page 8: ...8 Figure 4 Sch ma type d une installation une zone Figure 5 Diagramme multizone avec plus d un circulateur...

Page 9: ...9 Figure 6 Diagramme multizone avec valves motoris es Figure 7 Diagramme lectrique...

Page 10: ...10 SECTION 6 PI CES DE REMPLACEMENT Figure 8 Vue explos e...

Page 11: ...RE 1 ELEMENT Chaudi re seulement 14 B03977 02 ASS CHAUDI RE 2 ELEMENTS Chaudi re seulement 15 R02L006 THERMOMANOMETRE 1 4 NPT 16 B03984 01 ASS COUVERCLE Comprend couvercle cosmetique et diagramme lect...

Page 12: ......

Page 13: ...ner s Manual Dettson Industries Inc Manufactured by 3400 Industrial Boulevard Sherbrooke Qc Canada J1L 1V8 Attention Do not tamper with the unit or its controls Call a qualified service technician Pri...

Page 14: ...y where the equipment was purchased Upon completion of the installation this manual should be placed back into its original envelope and kept near the boiler for future reference 1 3 DELIVERY Upon del...

Page 15: ...an enclosure provide a door or a removable panel in front to access the control panel 1 6 DISTRIBUTION SYSTEM The proper functioning of your heating system is directly related to the quality of the pl...

Page 16: ...n water supply in the building b 1 expansion tank pre pressurized to 12 psi and of appropriate size c 1 or more automatic air purge valves d 1 or more circulating pumps of appropriate capacity CAUTION...

Page 17: ...hen using 208V change the connector s position at the primary of the transformer Refer to the boiler nameplate and the technical specifications in this manual to select the proper breaker and wire siz...

Page 18: ...nit is installed does not exceed 27o C 80o F CAUTION The boiler guaranty may be invalidated if water leaks in the system are not repaired the boiler is used as a source of domestic hot water or a sign...

Page 19: ...5 3 3 9 4 12 5 12 15 6 0 81 1 08 3 4 4 12 5 16 7 15 6 20 9 1 08 1 44 3 75 5 5 15 6 20 8 19 5 26 1 35 1 81 4 5 6 3 3 18 8 25 0 23 5 31 3 1 63 2 17 5 25 7 4 3 21 9 29 2 27 4 36 5 1 90 2 53 6 8 4 4 25 33...

Page 20: ...8 Figure 4 Typical Diagram of a Single Zone Installation Figure 5 Multizone Diagram with more than one Circulator...

Page 21: ...9 Figure 6 Multizone diagram with Motorized Valves Figure 7 Electrical Diagram...

Page 22: ...10 SECTION 6 REMPLACEMENT PARTS Figure 8 Exploded Vue...

Page 23: ...LER ASSEMBLY 1 ELEMENT Boiler only 14 B03977 02 BOILER ASSEMBLY 2 ELEMENTS Boiler only 15 R02L006 TRIDICATOR 1 4 NPT 16 B03984 01 COVER ASSEMBLY Cover cosmetic and wiring diagram included 17 B04000 02...

Page 24: ......

Reviews: