![Detroit Diesel EPA04 MBE 900 Operator'S Manual Download Page 76](http://html.mh-extra.com/html/detroit-diesel/epa04-mbe-900/epa04-mbe-900_operators-manual_2488037076.webp)
TECHNICAL DATA
Testing and Adjusting
Values
Valve lash checking and adjustments
are listed in Table 11. Engine
Oil Pressure is listed in Table 12.
Coolant thermostat conditions are
listed in Table 13. Injector pressures
are listed in Table 14.
Valve Type
Check For:
mm ( in.)
Adjust To:
mm ( in.)
Intake
0.30 to 0.60 (0.012 to 0.024)
0.016 (0.40)
Exhaust
0.50 to 0.80 (0.020 to 0.032)
0.60 (0.024)
Table 11
Valve Lash Checking and Adjustment
Engine Speed
Minimum Pressure
At idling rpm
50 kPa (7 psi)
At maximum rpm
250 kPa (36 psi)
Table 12 Engine Oil Pressure
Condition
Speci
fi
cation
Starts to open
81 to 85°C (177 to 185°F)
Fully open
95°C (203°F)
Minimum lift
8 mm ( 0.3 in.)
Table 13 Coolant Thermostat
Opening Pressure
Value in kPa (psi)
Minimum opening pressure
24,497 (3,553)
Maximum opening pressure
25,697 (3,727)
Table 14 Injector Pressure
66
All information subject to change without notice.
(Rev. )
DDC-SVC-MAN-0055
Copyright © 2009 DETROIT DIESEL CORPORATION
Summary of Contents for EPA04 MBE 900