OPERATION
Checking the Coolant Level
(Cold Check)
Check the coolant level as follows:
1. Ensure that all coolant plugs in
the bottom of the radiator and on
the radiator outlet pipe are secure
and tight.
2. Check the coolant level. The
cooling system is correctly
fi
lled
when the coolant is between the
maximum and minimum marks
on the surge tank.
NOTE:
For more information, refer to the
”Maintenance” section.
Adding Fuel
Note the following when adding fuel:
□
Add winter or summer grade fuel
according to the season of the
year.
□
Work in the cleanest conditions
possible.
□
Prevent water from entering the
fuel tank. For further information
refer to “Diesel Fuels” in “Service
Products.”
Priming the Fuel System
Prime the fuel system as follows:
NOTICE:
Correct torque on the high pressure
lines is critical. Incorrect torques
could result in leaks or lack of power
due to restricted fuel flow.
1. Make sure that all high-pressure
and low-pressure lines are
securely tightened.
2. If equipped with a hand pump on
the fuel/water separator, work the
hand pump 50 times.
3. Crank the engine for 30 seconds
at a time, but
no longer.
Before
cranking the engine again, wait
at least two minutes. The engine
should start within six 30-second
attempts.
Starting the Engine
Before operating the engine, follow
the steps described in the “Before
Starting the Engine” section. Start the
engine as follows:
NOTE:
As a safety function, the electronic
engine control system may be wired to
start the engine only if the transmission
is in neutral. This is vehicle application
specific.