123
Frequently Asked Questions
DECT
DECT
Question: The LED of the RFP 21/
23is flashing, but none of the DECT
devices is functioning.
Make sure the terminal setting for
the corresponding U
pn
port is set to
RFP 21/23
(
Configurator
,
PBX Con-
figuration: Ports: U
pn
menu).
Question: The LED of the RFP 21/
23 is continuously lit up, but one of
the cordless DECT devices is indi-
cating “No connection”.
You have not configured a port for
this DECT device. Configure a port in
the
Configurator
and start the en-
rolment procedure (
PBX Configura-
tion: Ports: DECT-PP
menu).
Question: Is it possible to increase
the time for the enrolment proce-
dure?
You must manually enter the IPEI of
the DECT device in the
Configurator
.
The enrolment time is then in-
creased to one hour (
PBX Configura-
tion: Ports: DECT-PP
menu).
Question: Another manufac-
turer’s DECT device is not function-
ing.
Check whether the DECT device sup-
ports the DECT GAP standard. In the
Configurator
, also make sure
GAP
is
set for this DECT device (
PBX Config-
uration: Ports: DECT-PP
menu).
Question: The startup procedure
of the RFP 21/23 take a long time?
What is the reason?
This behaviour may indicate a prob-
lem with the reference clock. Refer
also to