- Page 16 -
APPENDIX
– A5
Troubleshooting
PROBLEM
CAUSE
SOLUTIONS
Leak on the pressure
regulator in front of the
control panel
Loosened regulation
cable gland
Tighten the cable gland
with a 12 wrench.
Noisy HP pump.
-
Reduced water inlet
or air inlet in the
system.
- Leak on pump head
seals.
-
Ensure correct size of
hoses (diameter), clips
and filters secure and
filters clean.
-
Replace seals.
Oil leak on HP pump
Worn seals on
connecting rods
-
Replace the seals.
Insufficient water flow
-
Very cold water
-
Dirty pre filter
-
Tension drop on the
power cable
-
Replace the pre filter
-
Recharge batteries
-
Check the connection.
-
Inadequate power
cable section,
reinforce cable
section.
Water leak under the
HP head
- Worn seals
- Replace plunger seals
No pressure reading
Insufficient water
Open the hull valve and /
or the rinsing valve
Pressure doesn’t come
up.
Dirty pump valves
Dismantle and clean the
valves in the pump head
Summary of Contents for DUO100