- Page 4 -
2. How to install the desalinator:
2.4 Membrane unit
3
1
2
The membranes can be installed horizontally,
preferably flat or on a wall support. They are
mounted using 8 Parker screws in
stainless
steel brackets
1
. As the hose from the HP
pump
2
vibrates, it is preferable to install the
hose with an insulating tube. The HP
connectors should be installed strictly in
accordance with the instructions (Appendix
A2). Apply a little loctite or nut seal to the two
male and female cones before tightening.
Recommendation:
To facilitate the connection
3
, it is possible to rotate the heads
through 90° by unscrewing the grey production connectors. Remove the nut covers and
loosen the 12 nuts maintaining the unit. Remove the rod to obtain access and rotate the
membrane head using a box wrench to join the stainless steel connector. Reinstall the
rod and tighten the assembly.
Summary of Contents for DUO100
Page 4: ......
Page 21: ...Page 17 APPENDIX A5 Troubleshooting led indicator...