background image

- Page 3 - 

 

2. How to install the DUO 100: 

 

2.2 Motor unit: 

 

 

 
 
               

The HP motor unit should be installed as low as possible in the boat in 
a  horizontal  position  and  it  must  be  protected  from  water  spray  as 
much as possible. The unit is mounted using two brackets  under the 
two motors leaving a few centimetres clear space around the unit, to 
get  sufficient  air  circulation  space  for  motor  cooling.  The  connection 
between  the  prefilter

1

  oulet  and  the  inlet  to  the  low  pressure  side  of 

the  pump

2

  is  in  Tricoflex  hose  of 

  12mm  with  doubled  stainless 

jubilee clips at each joint. 
The  HP  head  of  the  pump  is  connected  to  the  membrane  inlet  (red 
mark)  through  an  HP  pipe,  cut  to  the  appropriate  length  (see 
installation of connectors appendix A2). 
Apply  a  little  liquid  Loctite  or  nut  seal  on  the  male  and female  cones 
before joining. 

 

 

         

 

 

 

2.3 Electrical connections: 

 

Negative battery cable

4

 

                      Positive battery cable

3

                      Please connect a fuse   
                      holder to this cable.                     

 

Neutral (blue)     phase (brown) 

 

Ground (Yellow / green) 

 
 
 

 

 
 
 

CAUTION: POWER SUPPLY SHOULD BE SWITCHED 

OFF BEFORE WORK IS CARRIED OUT. 

 

When  connecting  the  12  or  24V  motor  ensure  that  the 
polarity  is  correct:  positive  (brown  wire

3

)  on  the  relay  and 

negative  (green/yellow  wire

4

)  on  the  12  or  24V  motor. 

Depending  on  the  voltage  install  a  12V  fuse  holder 
(supplied) or a 24V circuit breaker (supplied) on the positive 
cable.  Ensure  that  the  cable  is  of  sufficient  diameter: 
35mm² for the 12V or 20mm² for the 24V.  
The Dessalator control cable is 5m long and is equipped 
with a plug with a pin locator system. The Dessalator® can 
only be operated when the power cable is connected to a 
DC supply. 
The  120  V  or  230  V  motor  is  connected  using  the  cable 
from  the  control  panel,  taking  care  to  respect  the 
connections on the terminal strip. 

2

 

 

Summary of Contents for DUO100

Page 1: ...d wide producing 100 L Hr with automatic rinsing model patented DESSALATOR Technical and Sales Departments Z I des 3 Moulins Euro 92 B t D rue des Cistes 06600 ANTIBES FRANCE Tel 33 0 4 93 95 04 55 Fa...

Page 2: ...g the membranes page 8 5 2 Rinsing the membranes page 9 5 3 Sterilizing the membranes page 10 5 4 High pressure pump page 10 6 Spare parts and accessories page 11 Appendix A1 Reverse osmosis page 12 A...

Page 3: ...es Length 700 Width 270 Height 120 N 1 HP Control panel Length 320 Width 200 Depth 150 Motor 12 V or 24 V I n s t a l l a t i o n d i a g r a m D e s s a l a t o r D U O 1 0 0 A C D C B i p o w e r e...

Page 4: ......

Page 5: ...ventilated space BEWARE In 120V please think of an even more important ventilation of the motor unit than in 230V Membrane unit The membrane unit includes 3 membranes 2521 assembled in a compact fram...

Page 6: ...the output of your board pump An electro valve is mounted on the output diam 12 for automatic rinsing It can be connected under a sink a wash basin or on the way of pressurized cold water hoses The va...

Page 7: ...the male and female cones before joining 2 3 Electrical connections Negative battery cable 4 Positive battery cable 3 Please connect a fuse holder to this cable Neutral blue phase brown Ground Yellow...

Page 8: ...ors should be installed strictly in accordance with the instructions Appendix A2 Apply a little loctite or nut seal to the two male and female cones before tightening Recommendation To facilitate the...

Page 9: ...alve on the fresh water tank outlet A Tricoflex waste oulet inner 12mm hose4 will also be required which can be connected to a sink wash basin or cockpit water drain to avoid having the hull redrilled...

Page 10: ...h on 5 Turn the pressure regulator dial to the right until the HP gauge reading is in the orange zone then gradually adjust until the needle reaches the beginning of the green zone Check that the pres...

Page 11: ...e exposed to temperatures above 60 C as high temperatures may also prevent salt from being removed Drying out of the membranes The membranes should be permanently immersed in liquid either sea water b...

Page 12: ...r produced falls it does not necessarily mean that the membrane needs to be replaced 5 2 Rinsing the membranes Once a week the watermaker needs to be flushed with fresh water before using it to make f...

Page 13: ...panel will turn on which indicates that flushing is in process This should take 30 seconds and will stop automatically The green and orange lights will shut off and the only indicator will be the blue...

Page 14: ...g a garden spray Pour the entire packet contents of sterilizer into a bucket containing 8 litres of fresh water and mix thoroughly Fill the spray bottle with this mixture and spray the sterilizer into...

Page 15: ...lways possible running without enough water accidental overpressure impact Should the need arise we supply spare parts and maintenance accessories 5 m 10 ft filter driving belt motor relays production...

Page 16: ...onsumable Pay attention not to allow chlorine into the desalination system as this could damage the device How does your desalinator work Sea water enters the inlet valve which penetrates the hull Thi...

Page 17: ...p where the steel threading disappears into the brass end piece a gap of approximately 7mm between the nut and the brass union 4 Unscrew the nut of the tapered adaptor The connector is now ready for t...

Page 18: ...re filter Remove the 5 m cartridge from the pre filter 10 Replace with the sterilizing cartridge ST2 Replace the 5 m cartridge with the sterilizing cartridge ST2 11 Set the rinsing valve to pressurize...

Page 19: ...it manually MANUAL RINSING Your Dessalator is equipped with an automated rinsing Here below the procedure to rinse manually HP pump Fresh water inlet Sea water inlet HP pump Fresh water inlet Sea wate...

Page 20: ...and filters clean Replace seals Oil leak on HP pump Worn seals on connecting rods Replace the seals Insufficient water flow Very cold water Dirty pre filter Tension drop on the power cable Replace the...

Page 21: ...Page 17 APPENDIX A5 Troubleshooting led indicator...