Figure 39 - Typical Flame Pattern
P35(B) and VP35(B) Models
P34 and VP34 Models
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or float
-
ing. Flames should go up through the middle
of log set. Flames should not "spill" to the
edges of the pan or sides of the log set.
Figure 39 shows a typical flame pattern. If burn
-
er flame pattern differs from that described:
• turn appliance off (see
To Turn Off Gas to
Appliance,
page 0)
• see
Troubleshooting
, page 22
INSPECTING BURNERS
Continued
CLEANING AND
MAINTENANCE
WARNING: Installation and
repair should be done by a quali-
fied service person. The appli-
ance should be inspected before
each use and at least annually
by a qualified service person.
More frequent cleaning may be
required due to excessive lint
from carpeting, bedding mate-
rial, pet hair, etc. It is imperative
that the control compartments,
burners, and circulating air sys-
tem be kept clean.
WARNING: Logs can be hot.
Handle only when cool.
WARNING: Turn off gas and
electrical power before servicing
appliance.
PILOT AND BURNER
• Remove logs and ember material before
cleaning burner and replace when cleaning
is complete.
• Burner and controls should be cleaned
with compressed air to remove dust, dirt,
or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to
log placement information on page 16 to
properly replace logs.
• Use a vacuum cleaner to remove any
carbon buildup on logs.
• Replace log(s) if broken. See
Replacement
Parts,
page 5.
• Replace ember material periodically as
needed. See
Replacement Parts,
page 5.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low if using
propane/LP gas
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about instal-
lation, operation, or troubleshooting. If so,
contact DESA’s Technical Service Department
at 1-866-672-6040. When calling, please
have your model and serial numbers of your
heater ready.,
You can also visit DESA’s technical services
web site at