www.desatech.com
108660-01E
7
Figure 2 - Possible Locations for
Installing Fireplace
INTERNAL WALL
INSTALLATION
CORNER
INSTALLATION
FULL
PROJECTION
INSTALLATION
FLUSH
INSTALLATION
PREINSTALLATION
PREPARATION
CLEARANCES
Minimum clearances to combustibles are:
• Top of Spacers . . . . . . . . . . . . . .0" min.
• Back and Sides of Outer
Surround. . . . . . . . . . . . . . . . . . .0" min.
• Drywall to Sides of Front
Face (Nailing Flanges) . . . . . . . .0" min.
• “B” Vent Surfaces . . . . . . . . . . . .1" min.
• Ceiling to Opening . . . . . . . . . .4" min.
• Floor . . . . . . . . . . . . . . . . . . . . . .0" min.
• Perpendicular Wall
See Figure 6, page 8
CAUTION: Do not block re-
quired air spaces with insulation or
any other material. Do not obstruct
effective opening of appliance with
any type of facing material.
Figure 3 - Minimum Clearances
(Top View)
0"
0" Clearance
Nailing
Flange
Front Face
Left Side Surround
Back
Drywall
x 4 Stud
SELECTING LOCATION
To determine the safest and most efficient
location for your appliance, you must take into
consideration the following guidelines:
1. The location must allow for proper clear-
ances (see
Clearances
).
. Consider a location where heat output
would not be affected by drafts, air con
-
ditioning ducts, windows, or doors.
3. A location that avoids the cutting of joists
or roof rafters will make installation easier.
Figure shows a plan view of a few com-
mon locations.
Flush installations
are recommended where
living space is limited or at a premium, and
since the space required to enclose the ap-
pliance would be located beyond an outside
wall, this would also reduce the cutting of
joists, roof rafters, and such. Check local
codes for any restrictions.
Projected installations
can extend any
distance into the room. A projection may
be ideal for a new addition on an existing,
finished wall.
Corner installations
make use of space
that may not normally be used and provides
a wider and more efficient range for radiant
heat transference.
Internal wall installations
provide a discreet
option for room separation and can also be
ideal as an addition to an existing wall.