www.desatech.com
108660-01E
17
COMBUSTION AIR KIT MODEL AK4
(OPTIONAL)
The outside air kit may be installed on the
left side of the fireplace only. The vent can
be installed through the outside wall or a
ventilated crawl space. The handle to operate
the damper door for the outside air inlet will
be located inside the left “screen pocket” of
the firebox (see Figure 31). Pull the handle to
open or push to close.
CAUTION: Air inlet ducts are
not to terminate in attic space.
Figure 31 - Air Kit Handle Location
Air Kit
Handle
Screen
Pocket
APPLIANCE ENCLOSURE
Before finishing enclosure around appliance,
inspect all joints around outer surround. Any
gaps between nailing flanges and framing
should be sealed with noncombustible insula-
tion or caulking (see Figure 3).
If appliance is mounted on a raised platform,
it must be a continuous surface and not
on blocks without a solid surface. This will
prevent the entry of cold air by means of
conduction through the total bottom of the
appliance.
INSTALLATION
Continued
Side
Framing
Side
Framing
Caulk Here
Pack
Insulation
Figure 32 - Sealing Between Appliance
and Framing
INSTALLING OPTIONAL GLASS
DOOR ACCESSORY
CAUTION: Use only glass
doors certified for use with this
appliance.
Note:
Assistance with installation may be
needed as glass doors are heavy.
These B-vent fireplaces are approved for use
with optional bi-fold glass doors (see
Acces-
sories
, page 25). The glass panels may be
ordered and installed anytime after the fire
-
place installation is complete.
Follow these steps to install left and right
panels:
1. With handle at the bottom, completely fold
panel on its hinges.
2. With handle facing center of firebox open
-
ing, insert lower pivot pin on glass door
panel into hole in pivot plate on bottom edge
of fireplace opening (see Figure 33).
Figure 33 - Installing Optional Glass
Door
Spring Clip
Insert Pin Into
Spring Clip
Insert Bottom
Pivot Pin
Into Pivot
Plate and
Swing Door
Into Vertical
Position
Pivot
Plate
Slide Top Pin Into
Door Track