6.  Keep all air openings in front and bottom of 

heater clear and free of debris. This will insure 

enough air for proper combustion. 

7.  If heater shuts off, do not relight until you 

provide  fresh,  outside  air.  If  heater  keeps 

shutting off, have it serviced.

8.  Do not run heater

• where flammable liquids or vapors are used 

or stored

• under dusty conditions

9.  Do not use heater if any part has been under 

water. Immediately call a qualified service 

technician to inspect the room heater and to 

replace any part of the control system and any 

gas control which has been under water. 

10.  Turn off and let cool before servicing. Only 

a qualified service person should service and 

repair heater. 

11.  Operating heater above elevations of 4,500 

feet could cause pilot outage. 

12.  To prevent performance problems, do not use 

propane/LP fuel tank of less than 100 lbs. 

capacity (propane/LP models only).

13.  Provide  adequate  clearances  around  air 

openings.

LOCAL CODES

Install and use heater with care. Follow all lo-

cal codes. In the absence of local codes, use the 

latest edition of

 National Fuel Gas Code, ANSI 

Z223.1/NFPA 54*

.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1.  Remove heater from carton.
2.  Remove all protective packaging applied to 

heater for shipment.

3.  Check  heater  for  any  shipping  damage.  If 

heater is damaged, promptly return to dealer 

where you bought heater.

SAFETY INFORMATION

Continued

Figure 1 - Vent-Free Gas Heater

Ignitor 
Button

Heater
Cabinet

Front Panel

Glass Panel

Grill Guard

Control 
Knob

PRODUCT INFORMATION

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The 

ODS/pilot is a required feature for vent-free room 

heaters. The ODS/pilot shuts off the heater if there 

is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re-

quires no matches, batteries or other sources to 

light heater.

THERMOSTATIC HEAT CONTROL

Thermostat  models  have  a  thermostat  sensing 

bulb and a control valve. This results in the great-

est heater comfort. This can also result in lower 

gas bills.

Summary of Contents for VP20BT

Page 1: ...other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s ph...

Page 2: ...ng plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer TABLE OF CONTENTS Safety Information 3 Local Codes 4...

Page 3: ...o high temperatures the appliance should be located out oftraf candawayfromfurniture and draperies Do not place clothing or other ammable material on or near the appliance Never place any objects on t...

Page 4: ...o cal codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018...

Page 5: ...e air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusual...

Page 6: ...rect vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater ______________ Btu Hr Vent free heater _____________ Btu Hr Total _____________ Btu Hr 40 000 20 00...

Page 7: ...t air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Figure 3 Ventilation Air from Outdoors Figure 2 Ventilation Air from Inside...

Page 8: ...es of the heater as a replace insert in high traf c areas in windy or drafty areas CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing h...

Page 9: ...Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to WallAnchor This method allows you to attach mounting bra...

Page 10: ...r ush to wall 4 For thin walls 1 2 or less insert red key into wall anchor Push red key to pop open anchor wings see Figure 10 IMPORTANT Do not hammer key For thick walls over 1 2 thick or solid walls...

Page 11: ...3 For carpeted oors make a small cut with a sharp knife at marked locations prior to drill ing If mounting base to a wood oor drill 1 8 inch diameter hole 3 4 inch deep Do not use anchors in wood oor...

Page 12: ...in Figure 15 Locate sediment trap where it is within reach for cleaning Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps the...

Page 13: ...by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter for n...

Page 14: ...de Pilot Burner Thermocouple OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a re or explosion may result causing property damage per son...

Page 15: ...lbetween1 and 5 Selecting the 5 setting will cause the burner to remain fully on without modulating down in most cases Note The thermostat sensing bulb measures the temperature of air near the heater...

Page 16: ...e of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can You can use a...

Page 17: ...25 x 7 24 25 x 25 75 x 7 Carton 26 25 x 21 25 x 9 26 25 x 29 x 9 Weight pounds Heater 20 28 Shipping 25 33 SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed i...

Page 18: ...on 4 Air in gas lines when in stalled 5 Depleted gas supply propane LP gas only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is n...

Page 19: ...Burner back ring during combustion Yellow ame during burner combustion Slightsmokeorodorduringinitial operation REMEDY 1 Press in control knob fully 2 AfterODS pilotlights keepcon trol knob pressed in...

Page 20: ...ly propane LP gas only 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged OBSERVED PROBLEM Heaterproducesawhistlingnoise wh...

Page 21: ...0 When calling DESA Heating Products have ready your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Us...

Page 22: ...www desatech com 107886 01J 22 ILLUSTRATED PARTS BREAKDOWN MODELS VN20BT VP20BT VN30BT VP30BT 2 3 5 6 8 9 10 10 11 12 13 14 16 18 19 4 7 1 15 17 20...

Page 23: ...01 Nut M5 2 11 110803 01 110803 02 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 110186 01 110186 01 Thermocouple Kit 1 12 103446 01 103446 01 103447 01 103447 01 Burner 1 13 099387 03...

Page 24: ...intenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of...

Reviews: