background image

www.desatech.com

55511E

15

ADjUSTABLE hOOD

 

Black - GA650, 01244 

Polished Brass -GA6052, 01245

 

Anitque Brass - GA6053

 

Chrome - 01246

FLAShING

 

(V)6F-8DM for 0 to 6/12 

Roof Pitch

 

(V)12F-8DM for 6/12 to 

12/12 Roof Pitch

DOUBLE WALL PIPE

 - (V)12-8DM, 

 

(V)18-8DM, (V)24-8DM, (V)36-8DM, 

 

(V)48-8DM
(Chimney pipe assembly includes outer 

and inner pipes and comes with wire 

spacer. Also available in triple wall)

DOUBLE WALL PIPE 

SUPPORT ASSEMBLY 

(V)

12S-8DM

 

(Also available in triple wall)

DOUBLE WALL 30° ELBOW/OFFSET 

(V)30E-8DM (Also available in triple wall)

FIRESTOP SPACER 

 

(V)FS-8DM 

for Straight 

Pipe (24 Pack)

ECONO TOP 

TERmINATION  

(V)ETL-8DM, 

 

(V)ETLO-8DM

Vent Plaster 

Collar

Vent Hood

Connector 

Duct - 4" x 3'

Return 

Elbow

Starter 

Elbow

STORM COLLAR 

 

(V)SC1-20-8DM 

 

(20 PACK) 

 

(for use with (V)RTL-8DM)

(V)SC2-20 (20 PACK)

 

(for use with (V)RTT-8DM and (V)RTTL-8DM)

rePLACeMenT And ACCeSSory PArTS

Continued

ROUND TOP 

TERmINATION  

(V)RTL-8DM, (V)RTTL-8DM

 

RT-8DM, RTL-8DM
ROUND TOP 

TERMINATION WITh SLIP 

SECTION

 

RTT-8DM, RTTL-8DM

OUTSIDE AIR KIT - AK4

EMBER PROTECTORS (2)

 

20093

GRATE 11168

Summary of Contents for (V)368ST

Page 1: ...72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard ThiswoodburningfireboxcomplieswithUL127 CAN ULS S610 M87standardasaFACTORYBUILTAPPLIANCEand is listed and test...

Page 2: ...ufacturer s instruc tions with the insert specifically statethisfireboxhasbeentested for use with the insert Thisfireboxisnotintendedtobe usedasasubstituteforafurnace to heat an entire home Use for su...

Page 3: ...e or stir the logs while they are burn ing Use only fire logs that have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARNIN...

Page 4: ...Typ Figure 3 Firebox Clearances Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall selecting location To determine the safest and most efficient location for the firebox you must take into...

Page 5: ...ing 1 Frame the opening for the firebox using the dimensions shown in Figures 6 and 7 depending on your installation 2 If firebox is to be installed directly on carpeting tile other than ceramic or an...

Page 6: ...ber Protector Noncombustible Hearth Extension Ember Protector Figure 11 Raised Hearth Extension Figure 9 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 1 27 cm Minimum to Combust...

Page 7: ...is to establish and maintain the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number V30FS 8DM see Replaceme...

Page 8: ...8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame 2 5 1cm Minimum Angled Firestop Ceiling Support Return Elbow 30 FT 9 14m 30 FT 9 14m Figure 16 Elbow Offset Return Elbow 12S 8DM Su...

Page 9: ...4 feet above the roof line use support wires to keep chimney secure Support wires may be attached to outer pipe of chimney with screws if screws do not penetrate inner flue pipe Minimum Maximum Chimn...

Page 10: ...mney Pipe Waterproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many s...

Page 11: ...ifications finishing firebox Installing Firebox Facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not...

Page 12: ...ncoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refra...

Page 13: ...e fully open or fully closed position only or a fire hazard may be created see Figure 30 or 31 A firebox equipped with glass doors operates much differently than a firebox with an open front A firebox...

Page 14: ...nition Young children should be care fully supervised when they are in the same room as firebox Technical Service You may have further questions about installa tion operation or troubleshooting If so...

Page 15: ...ly V 12S 8DM Also available in triple wall Double Wall 30 elbow Offset V 30E 8DM Also available in triple wall Firestop Spacer V FS 8DM for Straight Pipe 24 Pack Econo Top Termination V ETL 8DM V ETLO...

Page 16: ...A UPC Bi Fold GLASS DOORS DG368ST Brushed Brass DC368ST Platinum DBP368ST Black Replacement and Accessory Parts Continued DESA Heating LLC 2701 Industrial Drive Bowling Green KY 42101 www desatech com...

Reviews: