www.desatech.com
55511E
11
Secure
Termination
to Outer
Pipe with 3
Screws
RTL-8DM
Stainless
Inner Flue
Pipe
Apply
Waterproof
Caulking
Storm
Collar
Flashing
Underlap
Shingles
Figure 25 - Terminations
Overlap
Shingles (Top
and Sides of
Flashing Base)
VenTing inSTALLATion
Continued
ChASE INSTALLATIONS
Instructions for chase installations are
included with the chase style termination
chosen. In a multiple chase installation, be
sure to provide adequate distance between
terminations to prevent smoke spillage from
one termination to another. Terminations must
be separated a minimum of 30" center to cen
-
ter and stacked at a minimum vertical height
difference of 18" (see Figure 26).
Note:
If a decorative shroud is to be installed,
contact the manufacturer for specifications.
FINISHING FIREBOx
Installing Firebox Facing
Any noncombustible material may be used
for facing (glass, tile, brick, etc.) as long as
proper clearances are adhered to and firebox
openings are not obstructed in any way (see
Figure 27).
Use only heat resistant, noncombustible mor-
tar or adhesive when securing facing material
to front of firebox. When placing facing at
upper edge of effective opening of firebox,
provide “L” shaped piece of metal extending
full width of opening (see Figure 27).
Secure with sheet metal screws at a distance
high enough from edge so it doesn't interfere
with operation of doors. This assures that fac-
ing material will not block openings.
30" Min.
30" Min.
18"
Min.
Typ.
Figure 26 - Multiple Chase Installation
1"
Space
Screen
Chase
Top
1" Non-
com-
bustible
Spacer
“L” Shaped
Metal
Support
Noncombustible
Facing Material
Noncombustible
Facing Material
Do Not
Block
Opening
Figure 27 - Fireplace Facing (Your
Fireplace May Vary from Illustration)