Figure 28 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of 

Fireplace

Gas Line 

Conduit
Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Remove 

Knockout

 WARNING: A qualified ser

-

vice person must connect gas 

supply. Follow all local codes.

NOTICE: 

Before you proceed, make sure your 

gas supply is turned off.

A gas line may be installed for the purpose 

of installing a vented or vent-free decorative 

gas  appliance  available  through  your  local 

distributor. Use only 1/2" black iron pipe and 

appropriate  fittings.  When  installing  a  gas 

line, a shutoff valve designed for installation 

outside the appliance is recommended.
1.  Remove knockout indentation on refrac-

tory or firebrick wall located approximately 

2" above the refractory hearth floor. The 

knockout  indentation  must  be  firmly 

tapped  with  any  solid  object  such  as  a 

1/2"  dowel  until  it  is  released.  Remove 

fragmented  portions  of  refractory  (see 

Figure 28).

2.  Remove gas line cover plate located on 

rear  of  fireplace  and  pull  out  insulation 

from gas line conduit sleeve. Save insula-

tion for reuse. 

3.  Run 1/2" black iron gas line into the firebox 

through the rear at 11 

1

/

4

" from floor and 

through gas line conduit sleeve (if using 

a  raised  platform,  add  height).  Provide 

sufficient  gas  line  into  firebox  chamber 

for fitting connection (see Figure 29). 

 

Note: Secure incoming gas line to wood 

framing to provide rigidity for threaded end.

4.  Repack insulation around gas line and into 

sleeve opening. Seal any gaps between 

gas line and refractory knockout hole with 

refractory cement or commercial furnace 

cement, Install the gas appliance or cap 

off gas line if desired.

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough Threaded 

End for Fitting Connection

Figure 29 - Gas Line Installation

oPTionAL gAS Line inSTALLATion

  CAUTION:  All  gas  piping 

and connections must be tested 

for  leaks  after  the  installation 

is  completed.  After  ensuring 

that the gas valve is on, apply 

soap  and  water  solution  to  all 

connections and joints. Bubbles 

forming  show  a  leak.  Correct 

all leaks at once. DO NOT USE 

AN  OPEN  FLAME  FOR  LEAK 

TESTING AND DO NOT OPER

-

ATE ANY APPLIANCE IF A LEAK 

IS DETECTED. LEAK TESTING 

ShOULD BE DONE BY A QUALI

-

FIED SERVICE PERSON.

The  gas  pipe  is  intended  for  connection  to 

an unvented gas log set or a decorative gas 

appliance. 
If  using  an  unvented  gas  log  set,  ONLY 

UNVENTED GAS LOG SETS WHICH HAVE 

BEEN  FOUND  TO  COMPLY  WITH  THE 

STANDARDS  FOR  UNVENTED  ROOM 

HEATERS, ANS/IAS/AGA Z21.11.2, ARE TO 

BE INSTALLED IN THIS FIREBOX.
If installing a decorative gas appliance, the 

decorative gas appliance must comply with 

the 

Standard for Decorative Gas Appliances 

for  Installation  in  Solid  Fuel  Burning  Fire-

places, ANS Z21.60-1996

 and shall also be 

installed in accordance with the 

National Fuel 

Gas code, ANS Z223.1-1996

.

Summary of Contents for (V)368ST

Page 1: ...72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard ThiswoodburningfireboxcomplieswithUL127 CAN ULS S610 M87standardasaFACTORYBUILTAPPLIANCEand is listed and test...

Page 2: ...ufacturer s instruc tions with the insert specifically statethisfireboxhasbeentested for use with the insert Thisfireboxisnotintendedtobe usedasasubstituteforafurnace to heat an entire home Use for su...

Page 3: ...e or stir the logs while they are burn ing Use only fire logs that have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARNIN...

Page 4: ...Typ Figure 3 Firebox Clearances Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall selecting location To determine the safest and most efficient location for the firebox you must take into...

Page 5: ...ing 1 Frame the opening for the firebox using the dimensions shown in Figures 6 and 7 depending on your installation 2 If firebox is to be installed directly on carpeting tile other than ceramic or an...

Page 6: ...ber Protector Noncombustible Hearth Extension Ember Protector Figure 11 Raised Hearth Extension Figure 9 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 1 27 cm Minimum to Combust...

Page 7: ...is to establish and maintain the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number V30FS 8DM see Replaceme...

Page 8: ...8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame 2 5 1cm Minimum Angled Firestop Ceiling Support Return Elbow 30 FT 9 14m 30 FT 9 14m Figure 16 Elbow Offset Return Elbow 12S 8DM Su...

Page 9: ...4 feet above the roof line use support wires to keep chimney secure Support wires may be attached to outer pipe of chimney with screws if screws do not penetrate inner flue pipe Minimum Maximum Chimn...

Page 10: ...mney Pipe Waterproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many s...

Page 11: ...ifications finishing firebox Installing Firebox Facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not...

Page 12: ...ncoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refra...

Page 13: ...e fully open or fully closed position only or a fire hazard may be created see Figure 30 or 31 A firebox equipped with glass doors operates much differently than a firebox with an open front A firebox...

Page 14: ...nition Young children should be care fully supervised when they are in the same room as firebox Technical Service You may have further questions about installa tion operation or troubleshooting If so...

Page 15: ...ly V 12S 8DM Also available in triple wall Double Wall 30 elbow Offset V 30E 8DM Also available in triple wall Firestop Spacer V FS 8DM for Straight Pipe 24 Pack Econo Top Termination V ETL 8DM V ETLO...

Page 16: ...A UPC Bi Fold GLASS DOORS DG368ST Brushed Brass DC368ST Platinum DBP368ST Black Replacement and Accessory Parts Continued DESA Heating LLC 2701 Industrial Drive Bowling Green KY 42101 www desatech com...

Reviews: