WARNING: Improper installation, adjustment, altera

-

tion, service or maintenance can cause injury, property 

damage or loss of life. Refer to this manual for assis-

tance  or  additional  information.  Consult  a  qualified 

installer or local distributor.

TABLe oF ConTenTS

Safety .................................................................. 2

Product Dimensions ............................................ 3

Firebox Installation .............................................. 4

Venting Installation .............................................. 6

Optional Gas Line Installation............................ 12

Operation and Maintenance Guidelines ............ 13

Technical Service............................................... 14

Replacement and Accessory Parts.................... 14

SAFeTy

c.  Installation  and/or  operation  in  a 

manner  other  than  instructed  in  this 

manual.

d.  The burning of any other fuel not tested 

or approved by DESA Heating, LLC in 

this wood burning firebox.

Proper installation is the most important step 

in  ensuring  safe  and  continuous  operation 

of the fireplace. Although grounding may not 

be required by code in your area, it must be 

electrically grounded in accordance with lo-

cal codes or, in the absence of local codes, 

with the 

National Electrical Code, ANSI/NFPA 

70-1990

.

This firebox is intended for installation in ac

-

cordance with the 

National Fire Protection As-

sociation Standard for Chimneys, Fireplaces, 

Vent

and  Solid-Fuel  Burning  Fireplaces

NFPA  211

,  and  in  accordance  with  codes 

such as the 

BOCA Basic/National Code

, the 

Standard Mechanical Code

, and the 

Uniform 

Building Code

.

 WARNING: Do not install a 

firebox insert in this firebox un

-

less the manufacturer's instruc-

tions with the insert specifically 

state this firebox has been tested 

for use with the insert.

This firebox is not intended to be 

used as a substitute for a furnace 

to heat an entire home. Use for 

supplemental heat only.

IMPORTANT: Check local codes 

before installing this firebox.

This is a wood burning firebox intended and 

approved for installation in either residential 

homes or buildings of standard construction. 

This firebox system requires the utilization of a 

DESA Heating, LLC 8" double wall, snap-lock 

flue pipe system.
Glass doors are optional with this firebox and 

come in different styles. For more information 

see 

Glass Doors

, page 13).

The  model’s  serial  number  and  any  other 

specific rating information may be found on 

the  rating  plate  located  inside  the  firebox 

opening.

Before beginning the installation of the firebox, 

read these instructions through completely.

•  This DESA Heating, LLC firebox and its 

approved  components  are  safe  when 

installed  according  to  this  installation 

manual and operated as recommended 

by DESA Heating, LLC. Use only DESA 

Heating,  LLC  approved  components, 

which  have  been  designed  and  tested 

for the fireplace system. Failure to do this 

may cause a fire hazard.

•  The DESA Heating, LLC warranty will be 

voided by and DESA Heating, LLC dis-

claims any responsibility for the following 

actions.

a.  Modification  of  the  firebox  or  any  of 

the  components  manufactured  by 

DESA Heating, LLC unless otherwise 

permitted by DESA Heating, LLC.

b.  Use  of  a  firebox  insert  or  any  other 

component  part  not  approved  by 

DESA  Heating,  LLC  in  combination 

with a DESA Heating, LLC firebox.

Summary of Contents for (V)368ST

Page 1: ...72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard ThiswoodburningfireboxcomplieswithUL127 CAN ULS S610 M87standardasaFACTORYBUILTAPPLIANCEand is listed and test...

Page 2: ...ufacturer s instruc tions with the insert specifically statethisfireboxhasbeentested for use with the insert Thisfireboxisnotintendedtobe usedasasubstituteforafurnace to heat an entire home Use for su...

Page 3: ...e or stir the logs while they are burn ing Use only fire logs that have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARNIN...

Page 4: ...Typ Figure 3 Firebox Clearances Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall selecting location To determine the safest and most efficient location for the firebox you must take into...

Page 5: ...ing 1 Frame the opening for the firebox using the dimensions shown in Figures 6 and 7 depending on your installation 2 If firebox is to be installed directly on carpeting tile other than ceramic or an...

Page 6: ...ber Protector Noncombustible Hearth Extension Ember Protector Figure 11 Raised Hearth Extension Figure 9 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 1 27 cm Minimum to Combust...

Page 7: ...is to establish and maintain the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number V30FS 8DM see Replaceme...

Page 8: ...8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame 2 5 1cm Minimum Angled Firestop Ceiling Support Return Elbow 30 FT 9 14m 30 FT 9 14m Figure 16 Elbow Offset Return Elbow 12S 8DM Su...

Page 9: ...4 feet above the roof line use support wires to keep chimney secure Support wires may be attached to outer pipe of chimney with screws if screws do not penetrate inner flue pipe Minimum Maximum Chimn...

Page 10: ...mney Pipe Waterproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many s...

Page 11: ...ifications finishing firebox Installing Firebox Facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not...

Page 12: ...ncoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refra...

Page 13: ...e fully open or fully closed position only or a fire hazard may be created see Figure 30 or 31 A firebox equipped with glass doors operates much differently than a firebox with an open front A firebox...

Page 14: ...nition Young children should be care fully supervised when they are in the same room as firebox Technical Service You may have further questions about installa tion operation or troubleshooting If so...

Page 15: ...ly V 12S 8DM Also available in triple wall Double Wall 30 elbow Offset V 30E 8DM Also available in triple wall Firestop Spacer V FS 8DM for Straight Pipe 24 Pack Econo Top Termination V ETL 8DM V ETLO...

Page 16: ...A UPC Bi Fold GLASS DOORS DG368ST Brushed Brass DC368ST Platinum DBP368ST Black Replacement and Accessory Parts Continued DESA Heating LLC 2701 Industrial Drive Bowling Green KY 42101 www desatech com...

Reviews: