www.desatech.com

55511E

5

12 

3

/

8

" Dia.

(31.4 cm) Outer Pipe

2" (5.1 cm) Min. 
Clearance From Outer 
Pipes to Combustibles

1" (2.5 cm) Min.
To Combustibles

21 

5

/

16

"

(54 cm)

42 

5

/

8

"

(108 cm)

24"

(61 cm)

12"

(31 cm)

Figure 6 - Framing Clearances

Figure 7 - Framing Firebox with “Z” Type 

Ember Protectors

FireBox inSTALLATion

Continued

As Required by Design as Lon

g

as Ceiling Clearance Is Maintain

ed

53 

7

/

8

"

(136 cm) 

Min

.

44 

5

/

8

"

(113 cm)

Min

.

Platform Must be
Solid, Flat and
Fully Supported

22 

3

/

4

"

(58 cm

)

"Z" Type 

Ember Protector

(Not Supplied)

Figure 5 - Mantel Clearances to Metal 

Face

Front

Face

Fireplace Front View

Fireplace Side View

3" Nom.

(7.6 cm)

9" Min.

(22.8 cm)

12" Min.

(30.4 cm)

33°

6" Nom.

(15.2 cm)

1

/

2

" Max.

(3.8 cm)

Drywall

2" X 4" Stud

Combustible

Materials

Figure 4 - Mantel Clearances to 

Combustible Materials

Seal Gaps with

Noncombustible

Mortar or Adhesive

Top View of Fireplace

Drywall

4"

(Approx.)

(10.1 cm) 33°

Nom.

6" Nom.

(15.2 cm)

3

/

8

Min.

(11.1 cm)

Combustible

Material Must

Not Overlap

Black Metal

Front Face

3

/

4

" Max.

(6.98 cm)

FRAmING

1.  Frame the opening for the firebox using 

the dimensions shown in Figures 6 and 7 

depending on your installation.

2.  If  firebox  is  to  be  installed  directly  on 

carpeting, tile (other than ceramic) or any 

combustible  material  other  than  wood 

flooring, firebox must be installed upon a 

metal or wood panel extending full width 

and depth of firebox.

Figure 8 - Ember Protectors

3.  Set firebox directly in front of opening and 

slide unit back until nailing flanges touch 

side framing.

4.  Check the level of firebox and shim with 

sheet metal if necessary.

5.  Before securing firebox to prepared fram

-

ing, ember protector (provided) must be 

placed  between  hearth  extension  (not 

supplied) and under bottom front edge of 

firebox to protect against glowing embers 

(see Figure 8 and 

Hearth Extensions

 on 

page 6). If firebox is to be installed on a 

raised platform, a Z-type ember protector 

(not  supplied)  must  be  fabricated  to  fit 

your required platform height (see Figure 

7). The ember protector should be made 

of galvanized sheet metal (28 gauge mini

-

mum) to prevent corrosion.

6.  Secure  firebox  to  framing  at  nailing 

flanges located on sides of firebox (see 

Figure 9, page 6).

Ember 

Protector 

(Typ. 2 of 2)

1/2" 

(1.2 cm) 

Max.

Summary of Contents for (V)368ST

Page 1: ...72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard ThiswoodburningfireboxcomplieswithUL127 CAN ULS S610 M87standardasaFACTORYBUILTAPPLIANCEand is listed and test...

Page 2: ...ufacturer s instruc tions with the insert specifically statethisfireboxhasbeentested for use with the insert Thisfireboxisnotintendedtobe usedasasubstituteforafurnace to heat an entire home Use for su...

Page 3: ...e or stir the logs while they are burn ing Use only fire logs that have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARNIN...

Page 4: ...Typ Figure 3 Firebox Clearances Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall selecting location To determine the safest and most efficient location for the firebox you must take into...

Page 5: ...ing 1 Frame the opening for the firebox using the dimensions shown in Figures 6 and 7 depending on your installation 2 If firebox is to be installed directly on carpeting tile other than ceramic or an...

Page 6: ...ber Protector Noncombustible Hearth Extension Ember Protector Figure 11 Raised Hearth Extension Figure 9 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 1 27 cm Minimum to Combust...

Page 7: ...is to establish and maintain the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number V30FS 8DM see Replaceme...

Page 8: ...8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame 2 5 1cm Minimum Angled Firestop Ceiling Support Return Elbow 30 FT 9 14m 30 FT 9 14m Figure 16 Elbow Offset Return Elbow 12S 8DM Su...

Page 9: ...4 feet above the roof line use support wires to keep chimney secure Support wires may be attached to outer pipe of chimney with screws if screws do not penetrate inner flue pipe Minimum Maximum Chimn...

Page 10: ...mney Pipe Waterproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many s...

Page 11: ...ifications finishing firebox Installing Firebox Facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not...

Page 12: ...ncoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refra...

Page 13: ...e fully open or fully closed position only or a fire hazard may be created see Figure 30 or 31 A firebox equipped with glass doors operates much differently than a firebox with an open front A firebox...

Page 14: ...nition Young children should be care fully supervised when they are in the same room as firebox Technical Service You may have further questions about installa tion operation or troubleshooting If so...

Page 15: ...ly V 12S 8DM Also available in triple wall Double Wall 30 elbow Offset V 30E 8DM Also available in triple wall Firestop Spacer V FS 8DM for Straight Pipe 24 Pack Econo Top Termination V ETL 8DM V ETLO...

Page 16: ...A UPC Bi Fold GLASS DOORS DG368ST Brushed Brass DC368ST Platinum DBP368ST Black Replacement and Accessory Parts Continued DESA Heating LLC 2701 Industrial Drive Bowling Green KY 42101 www desatech com...

Reviews: