background image

21

106706

OWNER’S MANUAL

For more information, visit www.desatech.com

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the
proper flame height. Alterations may have
occurred during shipping and handling. Call
a qualified service person to readjust the
pilot if necessary.

The height of the thermopile must be 3/8" to
1/2" above the pilot flame as shown in
Figure 54. The flame from the pilot burner
must extend beyond the thermopile.

If your pilot assembly does not meet these
requirements:

• turn burner system off (see To Turn Off

Gas to Appliance, page 19)

• see Troubleshooting, pages 23 through 25

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or
floating. Flame patterns will be different
from unit to unit and will vary depending on
installation type and weather conditions.

If the vent configuration is installed incor-
rectly, the flames will lift or “ghost”. This
can be dangerous. Inspect the flames after
installation to ensure proper installation
and performance.

Figure 55 shows a typical flame pattern. If
burner flame pattern differs from that described:

• turn burner system off (see To Turn Off

Gas to Appliance, page 19)

• see Troubleshooting, pages 23 through 25

Figure 54 - Pilot Assembly

Figure 55 - Typical Flame Pattern

Thermopile

Pilot Burner

Piezo Ignitor

3/8" to 1/2"

OPERATING STOVE
WITH B-VENT
BURNER SYSTEM

Continued

OPERATING

OPTIONAL BLOWER

ACCESSORY

Blower controls are located on the left
side of the rear cover of stove (from front
of stove).

The DA3610TA thermostatically-con-
trolled blower has an ON setting and an
OFF setting. The blower will only run
when the switch is in the ON position. In
the OFF position, the blower will not
operate.

If you are using DA3610TA blower with
optional thermostat (wall mount or re-
mote control), your burner system and
blower will not turn on and off at the
same time. The burner system may run
for several minutes before the blower
turns on. After the heater modulates to
the pilot position, the blower will con-
tinue to run. The blower will shut off after
the burner system firebox temperature
decreases.

The blower helps distribute heated air
from the burner system. Periodically
check the top grates of the stove and
remove any dust, dirt, or other obstruc-
tions that will  hinder the flow of air.

OPERATING

OPTIONAL GWMT1

WALL MOUNTED

THERMOSTAT

Light the fireplace as instructed in Light-
ing Instructions
 on page 19. Set wall ther-
mostat to desired temperature.

This thermostat has been electronically
calibrated at the factory and requires no
adjustment or leveling.

 WARNING: Do not connect

the thermostat to a power source.
Electrical shock and/or a fire haz-
ard will occur.

Upon installation, the thermostat must
be allowed to stabilize at room tempera-
ture for a minimum of 30 minutes for
proper operation.

To turn the burner system off, adjust
thermostat to the lowest setting and turn
the gas control knob back to PILOT. The
pilot will remain lit.

IMPORTANT:

 To turn the pilot off,

turn the control knob on the heater to
the OFF position.

Summary of Contents for MSRBVN

Page 1: ...installationand operational procedures For as sistance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not foll...

Page 2: ...eated and sealed gas combustion products can spill into your home Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have the...

Page 3: ...gandventsvertically Heat is generated by both realistic flames and glowing embers When used without the blower accessory the stove with burner system requires no electricity making it ideal for emerge...

Page 4: ...d see Figures 3 and 4 4 This stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible material other tha...

Page 5: ...e Figure 7 Rest stove on drop cloth orblankettoavoidscratchingstoveedges 7 Remove remaining pallet wood at tached to bottom of stove body see Figure 8 Use an adjustable wrench to remove bolts 8 Fasten...

Page 6: ...ly face down on a protected surface Remove the two screws that hold the front plate onto the front surround plate see Figure 14 Save these screws 15 Remove the seven screws and washers that hold the s...

Page 7: ...Body INSTALLING OPTIONAL BLOWER ACCESSORY 1 Remove4hexscrewssecuringrearcover to back of stove body see Figure 18 2 Separate bottom cover from rear cover by loosening the 8 mounting screws see Figure...

Page 8: ...re to the other side of the thermal switch see Figure 20 10 Connect the white wire to the other ter minal on the blower motor assembly see Figure 20 Make sure the thermal switch has been properly inst...

Page 9: ...major load bearing partitions or members It is also impor tant to locate the base of the gas vent as near as possible to the heating appliance This heater must be properly connected to a venting syst...

Page 10: ...NSTALLATION Continued CHECKING VENT CAPACITY Complete all gas piping electrical and vent connections After adjusting the fireplace andlightingthemainburners allowacouple of minutes for warm up Hold a...

Page 11: ...onsfrom0 4500feet When installing this stove and burner sys tem at an elevation above 2000 feet in the USA you may need to decrease the input rating by changing the existing burner ori fice to a small...

Page 12: ...tance to flow and may reduce draft enough to cause spillage The pitch of lateral runs can also be a problem lateral runs should be pitched 1 4 rise per foot of hori zontal run from the appliance to th...

Page 13: ...ed with the appliance or you can purchase it from your dealer CSA Design Certified Equipment Shutoff Valve with 1 8 NPT Tap 3 Minimum Propane LP From External Regulator 11 W C to 14 W C Pressure Appro...

Page 14: ...ee Figure 32 Connect flare union to flex ible gas line attached to gas regulator of fireplace see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections CONNECTING STOVE AND BURN...

Page 15: ...Accessory INSTALLING OPTIONAL WALL MOUNTED SWITCH GWMS2 1 Connect one terminal of 25 ft wire for the wall switch to the TPTH terminal on the valve Connect remaining wire terminal to theTH terminal on...

Page 16: ...f the cover firmly and pull to separate from the base WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard will occur Figure37 BackViewofThermostatBase Feed wir...

Page 17: ...glass door to install logs lava rock and ember material To remove glass door you must first remove the front panel on stove body STOVE AND B VENT BURNER SYSTEM INSTALLATION Continued Figure 41 Instal...

Page 18: ...ury INSTALLING LOGS LAVA ROCK AND GLOWING EMBERS STOVE AND B VENT BURNER SYSTEM INSTALLATION Continued 1 2 3 4 Figure 45 Installing Log No 1 Figure 46 Installing Log No 2 Figure 47 Installing Log No 3...

Page 19: ...push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a f...

Page 20: ...will remain lit GHRCTA Series Operation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 53 The lights to the left of the button will show AUTO ON or OFF Figure52 Settingthe...

Page 21: ...AL BLOWER ACCESSORY Blower controls are located on the left side of the rear cover of stove from front of stove The DA3610TA thermostatically con trolled blower has an ON setting and an OFF setting Th...

Page 22: ...WARNING Only parts sup pliedbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page26 This glass door panel is a complete unit No substitute materials m...

Page 23: ...ot fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located...

Page 24: ...for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 22 or replace burner or...

Page 25: ...per log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted odors Burner system shuts off in use Gas odor even when control knob...

Page 26: ...elallwiresprior to disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswi...

Page 27: ...epartment at 1 877 SUNVAL1 for information You canalsowritetotheaddresslistedontheback page of this manual WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access to the operation...

Page 28: ...6706 SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSRBVN MSRBVP LO H I P I L O T OFF ON 4 4 17 18 19 21 23 1 23 4 23 2 23 3 16 4 22 10 5 11 8 1 9 25...

Page 29: ...43 Switch Screw 2 12 105468 01 Valve Bracket 1 13 105489 01 Valve Natural 1 105489 02 Valve Propane LP 1 14 105488 01 Pilot Assembly Natural 1 105488 02 Pilot Assembly Propane LP 1 15 102445 01 Ignito...

Page 30: ...106706 SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MC SERIES Indicates Color Suffix Designation 1R 1C 1L 5 8 8 7 4 6 5 5 7 1 7 2 5...

Page 31: ...lain Enamel Almond 4 Total Per Stove 1 104175 14 One Leg Porcelain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55...

Page 32: ...be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES...

Reviews: