16
CAST IRON STOVE AND BURNER SYSTEM
106706
SUN VALLEY STOVE COMPANY
For more information, visit www.desatech.com
INSTALLING OPTIONAL
WIRELESS HAND-HELD
REMOTE CONTROL
ACCESSORIES - GHRC AND
GHRCTA SERIES
Figure 39 - Installing Battery in Receiver
Receiver
Battery Clip
Terminal
Wires
LO
H
I
P
IL
O
T
OFF
ON
Figure 40 - Installing Remote Receiver
INSTALLING OPTIONAL WALL
MOUNTED THERMOSTAT -
GWMT1, GWMS2
WARNING: Installation must
be done by a qualified installer
familiar with low voltage wiring
procedures.
WARNING: Do not connect
this thermostat to any electrical
source! Electrical shock and/or
fire hazard will occur.
1.
Open lower door panel. The valve is
attached to the underside of the fire-
box assembly.
2.
Disconnect from the valve the wires
running from the ON/OFF switch.
3.
Connect one terminal of the wire for
the wall thermostat to the THTP termi-
nal on the valve. Connect remaining
wire terminal to the TH terminal on the
valve. Make sure that the wire termi-
nals are in the positions on the unit as
pictured in Figure 36. If wires are not
connected as shown the thermostat will
not work.
4.
Route the wire to a convenient loca-
tion to mount your thermostat (no out-
side wall).
IMPORTANT:
The wire
must not exceed 25 feet in length.
The thermostat should be mounted 54"
above the floor in a location where
there is good air circulation. Avoid
heat sources such as lamps, direct sun-
light, fireplace, or heat and air condi-
tioning ducts.
5.
Gently remove the cover of the ther-
mostat from the base. Grasp the sides
of the cover firmly and pull to separate
from the base.
WARNING: Do not connect
this thermostat to a power
source. Electrical shock and/or
fire hazard will occur.
Figure 37 - Back View of Thermostat Base
Feed wires through
rectangular slots
Figure 38 - Thermostat Base Terminal
“W” and “R”
STOVE AND B-VENT
BURNER SYSTEM
INSTALLATION
Continued
6.
Feed the electrical wires through the
rectangular slots (from the back) on
each side of the base (see Figure 37).
NOTICE: Only use alkaline bat-
teries (not included).
Installing Remote Receiver
1.
Open bottom door on stove body and
locate the switch plate on the left of the
valve bracket.
2.
Disconnect wires from THTP and TH
on control valve that lead to the switch
(see Figure 36, page 15). Discard
switch plate, screws, and nuts.
3.
Install 9-volt battery (not included) into
receiver battery clip and connect to ter-
minals (see Figure 39).
4.
Place receiver into valve bracket and
align holes (see Figure 40).
5.
Use push-in fasteners included with
receiver to secure to bracket.
6.
Connect the wires from the receiver to
the valve at TH and THTP (see Figure
36, page 15).
9-Volt Battery
7.
Connect one bare wire end to each ter-
minal (“W” and “R”) of the thermostat
base (see Figure 38).
8.
Install the base to the wall with screws
provided with thermostat.
9.
Move the temperature adjustment back
and forth to insure the bimetal is free
from restrictions.
10. Replace the cover onto the base. (Upon
installation, the thermostat must be al-
lowed to stabilize at room temperature
for a minimum of 30 minutes for proper
operation.)
11. Set the temperature adjustment to the
desired setting. This thermostat has been
electronically calibrated at the factory.
No adjustment or leveling is necessary.
W
R
Terminal “W”
Terminal “R”