Installation Items Needed
Before installing stove and burner system,
make sure you have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas con-
nector (if allowed by local codes) (not
provided)
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the CSA design-certified equipment
shutoff valve from your dealer.
For propane/LP connections only, the in-
staller must supply an external regulator.
The external regulator will reduce incoming
gas pressure. You must reduce incoming
gas pressure to between 11 and 14 inches of
water. If you do not reduce incoming gas
pressure, heater regulator damage could
occur. Install external regulator with the
vent pointing down as shown in Figure 30.
Pointing the vent down protects it from
freezing rain or sleet.
Continued
Figure 30 - External Regulator with Vent
Pointing Down (Propane/LP Only)
Propane/LP
Supply Tank
External
Regulator
Vent
Pointing
Down
STOVE AND B-VENT
BURNER SYSTEM
INSTALLATION
Continued
Cap Pipe Nipple Tee Joint
Figure 31 - Gas Connection
* The CSA design-certified equipment shutoff valve may be supplied with the appliance or
you can purchase it from your dealer.
CSA Design-
Certified Equipment
Shutoff Valve with
1/8" NPT Tap*
3" Minimum
Propane/LP - From
External Regulator (11"
W.C. to 14" W.C.
Pressure)
Approved Flexible
Gas Line
Sediment Trap/Drip Leg
Natural - From Gas
Meter (5" W.C. to 10.5"
W.C. Pressure )
CAUTION: Use pipe joint seal-
ant that is resistant to liquid pe-
troleum (LP) gas.
We recommend that you install a sediment
trap/drip leg in supply line as shown in
Figure 31. Locate sediment trap/drip leg
where it is within reach for cleaning. Install
in piping system between fuel supply and
heater. Locate sediment trap/drip leg where
trapped matter is not likely to freeze. A
sediment trap traps moisture and contami-
nants. This keeps them from going into
burner system gas controls. If sediment trap/
drip leg is not installed or is installed wrong,
burner system may not run properly.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.
Installation must include an equipment
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from burner system (see Figure 31).
Check your building codes for any special
requirements for locating equipment shutoff
valve to stove.
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.