background image

3

598-1311-00

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

Avoid aiming the control at:

•  Objects that change temperature rapidly, such as 

heating vents and air conditioners.

 These heat 

sources could cause false triggering.

•  Areas where 

pets or traffi c

 may trigger the control.

•  

Nearby large, light-colored objects

 refl ecting light 

may trigger the shut-off feature. Do not point other 
lights at the sensor.

NOTE:

  Sensor has about 1 

1

/

2

 minutes warm up period 

before it will detect motion. When fi rst turned 
on, wait about 1 

1

/

2

 minutes.

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

MIN MAX

 Maximum 

Range  Maximum

  

Coverage 

Angle

70 ft. 

(21 m)

8 ft. 

(2.4 m)

 

Least Sensitive 

Most Sensitive

The detector is most sensitive to motion across its fi eld 
of view.

  Loosen the clamp screw in the 

sensor ball joint and gently 
rotate the sensor.

  Walk through the coverage area 

noting where you are when the 
lights turn on (also, the LED will 
fl ash several times when motion 
is detected). Move the sensor 
head up, down, or sideways to 
change the coverage area. 

Keep 

the sensor at least 1" (2.5 
cm) away from the lamp.

  Adjust the RANGE as needed. 

RANGE set too high may 
increase false triggering.

 

Secure the sensor head by 
tightening the clamp screw.

 

Do not overtighten the screw.

  Set the amount of TIME you 

want the lights to stay on after motion is detected 
(1, 5, or 10 minutes).

SPECIFICATIONS

Range  . . . . . . . . . . . . .  Up to 70 ft. (21 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . .  Up to 180°
Electrical Load . . . . . . .  Up  to  250  Watts  Maximum 

Incandescent.

Power Requirements . .  120 VAC, 60 Hz
Operating Modes . . . . .  TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . .  1, 5, 10 minutes
Replacement lamp . . . . T3, 250W (or less) halogen 

120 VAC

DESA Specialty Products reserves the right to dis-
continue products and to change specifi cations at any 
time without incurring any obligation to incorporate new 
features in products previously sold.

180°

Motion

Motion

Sensor

  Turn the RANGE control to the mid position and 

the ON-TIME control to the TEST position.

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Summary of Contents for Motion Sensing Halogen Fixture 5525

Page 1: ...ST 10 5 1 TEST ON TIME TEST AUTO Move ON TIME Switch to 1 5 or 10 minutes Mode Switch Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST If you get confused while switchin...

Page 2: ...r eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp scr...

Page 3: ...everaltimeswhenmotion is detected Move the sensor head up down or sideways to changethecoveragearea Keep the sensor at least 1 2 5 cm away from the lamp Adjust the RANGE as needed RANGE set too high m...

Page 4: ...manship will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expend able items are not covered...

Page 5: ...segundo y pr ndalo de nuevo Resumen de las modalidades del interruptor Para PRUEBA Nota Cuando lo prenda por primera vez espere unos 1 1 2 minutos hasta que el circuito se calibre PRUEBA AUTOM MODO M...

Page 6: ...ndo termine Controles Controles Apertura del protector de l mpara INSTALACI N DE BOMBILLA Cuandocambiedel mpara apaguelaelectricidad y deje que el aparato se enfr e Quite la tapa de vidrio y quite la...

Page 7: ...el tornillo sujetador No lo apriete demasiado Fije el per odo de tiempo ON TIME que la luz debe quedarseprendidadespu sdedetectarmovimiento 1 5 10 minutos Lo menos sensible Lo m s sensible Detector El...

Page 8: ...do a estado o de provincia a provincia Por un per odo de 90 d as desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin car...

Reviews: