background image

2

598-1311-00

INSTALLATION

For easy installation, select an existing light with a wall 
switch for replacement.

For best performance, mount the fi xture about 8 ft. 
(2.4 m) above the ground.

W

IRE

 

THE

 L

IGHT

 C

ONTROL

B

ULB

 I

NSTALLATION

❒ 

When relamping, 

turn power off

 and let the fi xture 

cool.

❒ 

Remove glass cover and remove the old bulb by 
pushing the bulb towards the socket indicated on 
the metal refl ector.

❒ 

To insert the new bulb, follow the instructions printed 
on the metal refl ector.

❒ 

Check that the bulb is seated properly.

❒ 

Reinstall the glass cover.

CAUTION: To Avoid Fire Or Burn Hazards:

•  Allow fi xture to cool before touching. The bulb and 

the fi xture operate at high temperatures.

•  Keep fi xture at least 1" (2.5 cm) from combustible ma-

terials. Do not aim at objects closer than 3 ft. (1 m).

•  Use only T3, 250W (max.) tungsten halogen 120 

VAC lamps.

White

 to 

White

Black

 to 

Black

Connect any fi xture ground wire(s) and the cover plate 
ground screw to the junction box ground wire.

Gasket

Mounting Strap

Mounting 

Bolt

M

OUNT

 

THE

 L

IGHT

 C

ONTROL

  Align the Light Control cover plate and cover plate 

gasket. Secure with the mounting bolt.

  Push the Rubber Plug fi rmly into place.

  If a wet location junction box was not used, caulk 

the wall plate mounting surface with silicone weather 
sealant.

For eave mount only:

  Swing the sensor head towards the clamp screw 

joint.

If the sensor pops out of the ball joint, loosen the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

  Then rotate the sensor head clockwise 180° so 

the controls face down.

Controls

Eave Mount

For under eave installation, the sensor head must be 
rotated

 as shown in the next two steps for proper operation 

and to avoid the risk of electrical shock. Also 

for proper 

under eave operation,

 remove the protective backing 

from the Light Shield and stick on as shown below.

Controls

Controls

Clamp Screw

Wall Mount

Lens Retainer

Light Shield, 

with opening at 

this side

❒ 

Note the position of the various parts of the fi xture for 
the type of installation for your application and adjust 
the lamp head and sensor as shown below.

Lens Retainer

Light Shield 

Opening

Rubber 

Plug

 WARNING: Turn power off at circuit breaker 

or fuse.

  Remove the existing light fi xture.

❒ 

Install mounting strap to junction box using screws 
appropriate for your junction box.

  The plastic hanger can be used to hold the fi xture 

while wiring. The small end of the plastic hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.

  Thread all fi xture wires through the large holes in 

the gasket as shown.

  Connect the junction box wires to the light fi xture 

wires as shown. Twist together and secure with wire 
connectors.

Summary of Contents for Motion Sensing Halogen Fixture 5525

Page 1: ...ST 10 5 1 TEST ON TIME TEST AUTO Move ON TIME Switch to 1 5 or 10 minutes Mode Switch Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST If you get confused while switchin...

Page 2: ...r eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp scr...

Page 3: ...everaltimeswhenmotion is detected Move the sensor head up down or sideways to changethecoveragearea Keep the sensor at least 1 2 5 cm away from the lamp Adjust the RANGE as needed RANGE set too high m...

Page 4: ...manship will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expend able items are not covered...

Page 5: ...segundo y pr ndalo de nuevo Resumen de las modalidades del interruptor Para PRUEBA Nota Cuando lo prenda por primera vez espere unos 1 1 2 minutos hasta que el circuito se calibre PRUEBA AUTOM MODO M...

Page 6: ...ndo termine Controles Controles Apertura del protector de l mpara INSTALACI N DE BOMBILLA Cuandocambiedel mpara apaguelaelectricidad y deje que el aparato se enfr e Quite la tapa de vidrio y quite la...

Page 7: ...el tornillo sujetador No lo apriete demasiado Fije el per odo de tiempo ON TIME que la luz debe quedarseprendidadespu sdedetectarmovimiento 1 5 10 minutos Lo menos sensible Lo m s sensible Detector El...

Page 8: ...do a estado o de provincia a provincia Por un per odo de 90 d as desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin car...