background image

8

www.desatech.com

116238-01C

(Framing

Detail)

10 

3

/

4

"

(273 mm)

10 

3

/

4

" Inside Framing

(273 mm)

10 

3

/

4

"

(273 mm)

1

/

2

"

(216 mm)

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall

INSTALLATION PLANNING

There are two basic types of direct-vent installation:
•  Horizontal Termination
•  Vertical Termination 

Horizontal Termination Installation

IMPORTANT: 

Horizontal  square  terminations  require  only  in-

ner portion of wall firestop. Horizontal installations using round 

termination require exterior portion of wall firestop (see Figure 

14, page 10).
1.  Set the fireplace in its desired location and determine the route 

your horizontal venting will take. Do not secure the fireplace 

until all venting has been installed. Some installations require 

sliding the fireplace in and out of position to make final vent-

ing connections. Figures 14 through 18 on pages 10 through 

12 show different configurations for venting with horizontal 

termination that will help you decide which application best 

suits your installation. Check to see if wall studs or roof rafters 

are in the path of your desired venting route. If they are, you 

may want to adjust the location of the fireplace.

2.  Direct vent pipe sections and components are designed with 

special twist-lock connections.

 

Twist-Lock  Procedure:

 The female ends of the pipes have 

locking lugs (indentations). These lugs will slide straight into 

matching slots on the male ends of adjacent pipes. Push pipe 

sections together and twist one section clockwise approxi-

mately one-quarter turn until the sections are fully locked (see 

Figure 8). 

Note:

 Horizontal runs of vent must be supported 

every three feet. Use wall straps for this purpose.

3.  Use a 45° elbow to connect venting system to fireplace flue 

collar. The elbow is designed to be twist-locked onto the flue 

collar as described in step 2. 

IMPORTANT:

 Do not attempt 

to alter the configuration of the elbow by cutting, twisting, 

bending, etc.

4.  Assemble the desired combination of pipe and elbows to the 

fireplace flue collar. If there are long portions of venting run, 

pre-assembled pipe sections may be installed as subassemblies 

for convenience.

5.  Carefully determine the location where the vent pipe assembly 

will penetrate the outside wall. The center of the hole should 

line up with the center-line of the horizontal vent pipe. Mark the 

wall for a 10 

3

/

4

" x 10 

3

/

4

" square hole. Cut and frame the square 

hole in the exterior wall where the vent will be terminated. If 

the wall being penetrated is constructed of noncombustible 

material, such as masonry block or concrete, a 8 

1

/

2

" hole with 

zero clearance is acceptable (see Figure 9).

VENTING INSTALLATION 

INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning

Figure 8 - Vent Pipe Connections

Figure 9 - Vent Opening Requirements

Center 

of Hole

Female 

Locking 

Lugs

Male 

Slots

Summary of Contents for KC36NE Series

Page 1: ...a quali ed installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured mo bile home where not prohibited by state or local codes Thi...

Page 2: ...nual carefully and completely before trying to assemble operateor service this replace Improper use of this replace can cause serious injury or death from burns re explosions electrical shock and carb...

Page 3: ...per or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this replace Use only the gas type indicated on replace nameplate 14 This appliance when installed must be electrica...

Page 4: ...pliance Due to high temperatures do not locate this replace in high traf c areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your replace is to be inst...

Page 5: ...replace as a heat source FRAMING AND FINISHING Figure4showstypicalframingofthis replace Figure5showsfram ing for corner installation All minimum clearances must be met For available accessories for th...

Page 6: ...earance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall exte...

Page 7: ...wall restops when penetrating walls and restops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination WARNING Read all instru...

Page 8: ...cking lugs indentations These lugs will slide straight into matching slots on the male ends of adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter tur...

Page 9: ...the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit ush against the exterior fascia material 7 Combustible Exterior W...

Page 10: ...al minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Horizontal Terminatio...

Page 11: ...sement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requiring a vertical rise on building exteri...

Page 12: ...tion Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following con gurations show the minimum vertical rise re quirements for a horizontal system using two 90 elbows Venting with...

Page 13: ...ove framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the replace ue up through the restop Be sure all pipe and elbow connections are fully twist locked see Figure...

Page 14: ...Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon gurationUsingTwo90 Elbows V...

Page 15: ...with your local gas company for proper ori ce size identi cation When installing this replace at an elevation above 4500 feet in Canada check with local authorities Consult your localgas companyto hel...

Page 16: ...Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory PARTS LIST FOR VENTING KITS AND COMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall...

Page 17: ...LACE INSTALLATION Continued Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath rebox oor against lower right outside wall Thermodisc Figure...

Page 18: ...lator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator Vent Pointing Down 5 Mount the speed control box against the mounting plate provided in the lower replace cavity...

Page 19: ...s for turning on or shutting off the gas to the appliance Checkyourbuildingcodesforanyspecialrequirementsforlocating equipment shutoff valve to replaces Apply pipe joint sealant lightly to male NPT th...

Page 20: ...d on or near gas meter for natural gas replace 3 Make sure control knob of replace is in the OFF position 4 Check all joints from equipment shutoff valve to gas valve see Figure 34 for propane LP or F...

Page 21: ...leaning Glass Door See Cleaning and Maintenance on page 25 Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING LAVA ROCK AND GLOWING EMBERS It is very important to keep logs exactly as insta...

Page 22: ...39 Installing Rear Brick Panel Rear Brick Panel Left Side Brick Panel INSTALLING BRICK LINER MODELS BL36DA SA AND BL36DHA SA WARNING If replace has been running turn off and unplug replace Let cool b...

Page 23: ...he wall switch to the ON position 11 Visuallylocatethepilot Theignitorshouldbegintosparkand the main burner should ignite once ame appears at pilot If lighting the appliance for the rst time each seas...

Page 24: ...te control for the replace your replace and blower will not turn on and off at the same time The replacemayrunforseveralminutesbeforetheblower turns on After the heater modulates to the pilot position...

Page 25: ...rom glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door page 20 Vacuum all glass pieces with a shop vac CAUTION Do not vacuum if pieces are hot Use only the t...

Page 26: ...all air out of lines If after re peated attempts appliance does not light call for quali ed service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your...

Page 27: ...just after burner is lit or shut off Slight smoke or odor during initial operation Gas odor even when control knob is in OFF position Gas odor during combustion Glass soots Dark residue on logs or ins...

Page 28: ...TS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized retailers of this product If they can not...

Page 29: ...let Supply Pressure 5 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace Actual size of rebox Measurements do not 36 x 41 x 21 1 8 36 x 41 x 21 1 8 include nailing anges or 914 x 1041 x 537 mm 914 x 1...

Page 30: ...h com 116238 01C ILLUSTRATED PARTS BREAKDOWN Models KC36NE VKC36NE KC36PE VKC36PE ILLUSTRATED PARTS BREAKDOWN MODELS KC36NE VKC36NE KC36PE AND VKC36PE 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 15 1...

Page 31: ...ctory Brick Panel 1 12 see below see below Rear Refractory Brick Panel 1 13 see below see below Right Refractory Brick Panel 1 14 108719 01 108719 01 Screen Rod 1 15 12105 12105 Screen 2 16 11418 1141...

Page 32: ...2 2 3 13 9 11 6 12 14 18 17 17 18 19 20 16 14 8 4 5 22 23 24 21 31 33 32 30 29 28 25 27 26 ILLUSTRATED PARTS BREAKDOWN Models KC36NE VKC36NE KC36PE VKC36PE ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY...

Page 33: ...l 1 108866 02 Elec Pilot Assembly Propane LP 1 11 14569 Elec Valve Assembly Natural 1 14570 Elec Valve Assembly Propane LP 1 12 11165 Screw 10 x 5 8 Zinc 1 13 111913 01 Burner Base Gasket 1 14 14396 B...

Page 34: ...L36DSA Standard Refractory Brick Liner Kit BL36DHA Textured Refractory Herringbone Brick Liner Kit BL36DHSA Standard Refractory Herringbone Brick Liner Kit Thisbricklineraddsatouchofstyletoyourdirect...

Page 35: ...te School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to 74 999 75 0...

Page 36: ...36 www desatech com 116238 01C 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 37: ...______________________ ________________________________________________________________________________________________ ________________________________________________________________________________...

Page 38: ...and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT...

Reviews: