Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models 

Blower Wiring Diagram

 CAUTION: Label all wires prior to disconnection 

when  servicing  controls.  Wiring  errors  can  cause 

improper  and  dangerous  operation.  Verify  proper 

operation after servicing. 

INSTALLING GAS PIPING TO FIREPLACE 
LOCATION

 WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

 CAUTION: For propane/LP units, never connect 

fireplace  directly  to  the  propane/LP  supply.  This 

heater requires an external regulator (not supplied). 

Install the external regulator between the fireplace 

and propane/LP supply. 

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.
•  external regulator (supplied by installer)

•  piping (check local codes)

•  sealant (resistant to propane/LP gas)

•  equipment shutoff valve *

•  test gauge connection *

•  sediment trap

•  tee joint

•  pipe wrench

•  approved flexible gas line with gas connector (if allowed by local 

codes)

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap 

is an acceptable alternative to test gauge connection. Purchase the 

CSA design-certified equipment shutoff valve from your retailer.
For propane/LP connection only, the installer must supply an external 

regulator. The external regulator will reduce incoming gas pressure. 

You must reduce incoming gas pressure to between 11 and 14 inches 

of water. If you do not reduce incoming gas pressure, fireplace 

regulator damage could occur. Install external regulator with the 

vent pointing down as shown in Figure 31, page 19. Pointing the 

vent down protects it from freezing rain or sleet.

Figure 30 - External Regulator with Vent Pointing Down 

(Propane/LP Only)

Propane/LP 

Supply Tank 

External 

Regulator 

Vent 

Pointing 

Down 

5.   Mount the speed control box against the mounting plate provided 

in the lower fireplace cavity by placing the plastic control shaft 

forward through the round hole (see Figure 26, page 17).

6.  While supporting speed control, secure control shaft with lock 

nut by pushing and turning lock nut with pliers clockwise until 

it is tight against mounting plate. Place control knob provided 

on shaft (see Figure 26, page 17).

7.   Check to make sure that the power cord is completely clear of the 

blower wheel and that there are no other foreign objects in blower 

wheel. Also double check all wire leads and make sure wire routing 

is not pinched or in a precarious position. Correct accordingly. 

8.  Turn on power to duplex outlet if previously turned off per the 

warning in column 2, page 16.

9.   Plug in blower power cord to duplex outlet.
10.  The blower will only run when the speed control knob is in the 

ON position and the thermal switch senses temperature after the 

fireplace begins to heat up. The blower speed can be adjusted by 

rotating the control knob. To turn off, turn knob fully counterclock-

wise until it clicks off. If the blower is ON and has been running 

with the fireplace operating, the blower will continue to run for a 

short time after the fireplace has been turned off. As the thermal 

switch cools down, the blower shuts down automatically.

11.  Peel off the backing paper and stick the supplied wiring diagram 

decal on the firebox bottom approximately 12" in front of the 

blower (see Figure 27, page 17). 

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Installing Optional Blower Accessory (Cont.)
Installing Gas Piping to Fireplace Location

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115 

V.A.C.

Blower

Motor

Black 

Off

1

2

Black

Summary of Contents for KC36NE Series

Page 1: ...a quali ed installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured mo bile home where not prohibited by state or local codes Thi...

Page 2: ...nual carefully and completely before trying to assemble operateor service this replace Improper use of this replace can cause serious injury or death from burns re explosions electrical shock and carb...

Page 3: ...per or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this replace Use only the gas type indicated on replace nameplate 14 This appliance when installed must be electrica...

Page 4: ...pliance Due to high temperatures do not locate this replace in high traf c areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your replace is to be inst...

Page 5: ...replace as a heat source FRAMING AND FINISHING Figure4showstypicalframingofthis replace Figure5showsfram ing for corner installation All minimum clearances must be met For available accessories for th...

Page 6: ...earance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall exte...

Page 7: ...wall restops when penetrating walls and restops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination WARNING Read all instru...

Page 8: ...cking lugs indentations These lugs will slide straight into matching slots on the male ends of adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter tur...

Page 9: ...the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit ush against the exterior fascia material 7 Combustible Exterior W...

Page 10: ...al minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Horizontal Terminatio...

Page 11: ...sement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requiring a vertical rise on building exteri...

Page 12: ...tion Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following con gurations show the minimum vertical rise re quirements for a horizontal system using two 90 elbows Venting with...

Page 13: ...ove framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the replace ue up through the restop Be sure all pipe and elbow connections are fully twist locked see Figure...

Page 14: ...Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon gurationUsingTwo90 Elbows V...

Page 15: ...with your local gas company for proper ori ce size identi cation When installing this replace at an elevation above 4500 feet in Canada check with local authorities Consult your localgas companyto hel...

Page 16: ...Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory PARTS LIST FOR VENTING KITS AND COMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall...

Page 17: ...LACE INSTALLATION Continued Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath rebox oor against lower right outside wall Thermodisc Figure...

Page 18: ...lator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator Vent Pointing Down 5 Mount the speed control box against the mounting plate provided in the lower replace cavity...

Page 19: ...s for turning on or shutting off the gas to the appliance Checkyourbuildingcodesforanyspecialrequirementsforlocating equipment shutoff valve to replaces Apply pipe joint sealant lightly to male NPT th...

Page 20: ...d on or near gas meter for natural gas replace 3 Make sure control knob of replace is in the OFF position 4 Check all joints from equipment shutoff valve to gas valve see Figure 34 for propane LP or F...

Page 21: ...leaning Glass Door See Cleaning and Maintenance on page 25 Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING LAVA ROCK AND GLOWING EMBERS It is very important to keep logs exactly as insta...

Page 22: ...39 Installing Rear Brick Panel Rear Brick Panel Left Side Brick Panel INSTALLING BRICK LINER MODELS BL36DA SA AND BL36DHA SA WARNING If replace has been running turn off and unplug replace Let cool b...

Page 23: ...he wall switch to the ON position 11 Visuallylocatethepilot Theignitorshouldbegintosparkand the main burner should ignite once ame appears at pilot If lighting the appliance for the rst time each seas...

Page 24: ...te control for the replace your replace and blower will not turn on and off at the same time The replacemayrunforseveralminutesbeforetheblower turns on After the heater modulates to the pilot position...

Page 25: ...rom glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door page 20 Vacuum all glass pieces with a shop vac CAUTION Do not vacuum if pieces are hot Use only the t...

Page 26: ...all air out of lines If after re peated attempts appliance does not light call for quali ed service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your...

Page 27: ...just after burner is lit or shut off Slight smoke or odor during initial operation Gas odor even when control knob is in OFF position Gas odor during combustion Glass soots Dark residue on logs or ins...

Page 28: ...TS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized retailers of this product If they can not...

Page 29: ...let Supply Pressure 5 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace Actual size of rebox Measurements do not 36 x 41 x 21 1 8 36 x 41 x 21 1 8 include nailing anges or 914 x 1041 x 537 mm 914 x 1...

Page 30: ...h com 116238 01C ILLUSTRATED PARTS BREAKDOWN Models KC36NE VKC36NE KC36PE VKC36PE ILLUSTRATED PARTS BREAKDOWN MODELS KC36NE VKC36NE KC36PE AND VKC36PE 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 15 1...

Page 31: ...ctory Brick Panel 1 12 see below see below Rear Refractory Brick Panel 1 13 see below see below Right Refractory Brick Panel 1 14 108719 01 108719 01 Screen Rod 1 15 12105 12105 Screen 2 16 11418 1141...

Page 32: ...2 2 3 13 9 11 6 12 14 18 17 17 18 19 20 16 14 8 4 5 22 23 24 21 31 33 32 30 29 28 25 27 26 ILLUSTRATED PARTS BREAKDOWN Models KC36NE VKC36NE KC36PE VKC36PE ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY...

Page 33: ...l 1 108866 02 Elec Pilot Assembly Propane LP 1 11 14569 Elec Valve Assembly Natural 1 14570 Elec Valve Assembly Propane LP 1 12 11165 Screw 10 x 5 8 Zinc 1 13 111913 01 Burner Base Gasket 1 14 14396 B...

Page 34: ...L36DSA Standard Refractory Brick Liner Kit BL36DHA Textured Refractory Herringbone Brick Liner Kit BL36DHSA Standard Refractory Herringbone Brick Liner Kit Thisbricklineraddsatouchofstyletoyourdirect...

Page 35: ...te School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to 74 999 75 0...

Page 36: ...36 www desatech com 116238 01C 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 37: ...______________________ ________________________________________________________________________________________________ ________________________________________________________________________________...

Page 38: ...and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT...

Reviews: