INSTALLATION

Continued 

Figure 9 - Placement of Top Logs

Ember 
Chunks

OPERATING APPLIANCE

FOR YOUR SAFETY

READ BEFORE LIGHTING

 WARNING: Keep flue open 

when operating unit.

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

BEFORE  LIGHTING  smell  all  around  the 

appliance area for gas. Be sure to smell next to 

the floor because some gas is heavier than air 

and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use 

any phone in your building.

•  Immediately call your gas supplier from a 

neighborʼs phone. Follow the gas supplierʼs 

instructions.

•  If you cannot reach your gas supplier, call the 

fire department.

LIGHTING

 INSTRUCTIONS

1.  STOP!  Read  the  safety  information  on 

column 1.

2.  Turn the gas shutoff valve to OFF.

3.  Wait five (5) minutes to clear out any gas. If 

you then smell gas STOP! Follow the safety 

information column 1. If you don't smell 

gas, go on to the next step.

4.  Light a match and lay it on top of the pan 

material about 2" from the end of the sup-

ply side of the pan

5.  Slowly turn the gas shutoff valve ON until 

the burner ignites. If the burner doesnʼt 

ignite within 10 seconds with the match 

burning, turn the shutoff valve OFF and 

repeat steps 1 through 4 again.

GAS SHUTOFF

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the gas 

shutoff valve counterclockwise 

 to open 

or clockwise 

 to close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise 

  to the 

OFF position.

CURING  

LOGS

During the 2-3 hour appliance break-in period, 

you may detect an odor from the appliance 

as the various paints and compounds used in 

the manufacturing of this log set cure. This is 

a normal and temporary situation that is not 

cause for alarm. However, you may want to 

provide extra ventilation to the room during 

this time.

To ensure proper curing of the logs:

•  Ignite  a  2"  flame  and  maintain  it  for  1 

hour.

•  Burn the logs in consecutive 1 hour periods 

raising the flame an additional 2" to full 

flame height for a total of three hours.

Summary of Contents for Comfort Glow SYCAMORE SPLIT SMS18

Page 1: ...e WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the...

Page 2: ...tilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently loc...

Page 3: ...d and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING D...

Page 4: ...stored under dusty conditions 8 Do not burn solid fuel in the replace after installing the log set Do not use this log set to cook food or burn paper or other objects 9 Do not use appliance if any par...

Page 5: ...e make sure that all of the speci cations shown are applicable before installation is attempted The replace must include a working ue and venting system with the minimum openings shown in the Figure 2...

Page 6: ...p within reach for test gauge hook up NPT tap must be upstream from log set see Figure 4 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning...

Page 7: ...d Burner Inlet Venturi Attached to Pan Bottom Gas Connector Tube Figure 6 Connecting Gas to Appliance Adapter Fitting Burner Inlet Fitting Factory Installed 3 Check all joints from gas meter to equipm...

Page 8: ...serve the individual tongues of ame on the burner Make sure that all ports are clear and produc ing ame evenly across the burner If any ports appear blocked clear them by removing the burner manifold...

Page 9: ...P Follow the safety information column 1 If you don t smell gas go on to the next step 4 Light a match and lay it on top of the pan material about 2 from the end of the sup ply side of the pan 5 Slowl...

Page 10: ...ing please have your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com REPLACEMENT PARTS Note Use only original replacement par...

Page 11: ...2 Adjust damper wide open and or have replace and vent ing professionally cleaned and checked 3 Separate the logs to allow more ame passage 4 Removeanyforeignitemsfrom the ame pattern and or check fo...

Page 12: ...ace control valve 1 Locate and correct all leaks see Checking Gas Connec tions page 7 OBSERVED PROBLEM Log set produces a clicking tick ing noise just after burner is lit or shut off Log set produces...

Page 13: ...only 3 pine cones per box ASH BED MATERIAL VERMICULITE GA9750A Not Shown For all models Use for rebox decoration only GLOWING EMBERS GA9950A Not Shown For all models Use for rebox decoration only SIL...

Page 14: ...www desatech com 117536 01B 14 ILLUSTRATED PARTS BREAKDOWN MODELS SMS18 AND SMS24 1 8 9 10 23 13 11 17 16 15 22 21 20 3 2 4 5 6 7 12 14 18 19...

Page 15: ...1 8 901242 01 901242 01 Damper Clamp Std Assy 1 9 11209 11209 Nut 10 24 2 10 117244 01 117244 02 Log Grate 1 11 117250 01 117251 01 Front Bottom Left Log 1 12 117250 02 117251 02 Front Bottom Right L...

Page 16: ...s war ranty The log set MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in orig...