background image

www.desatech.com

117536-01B

5

INSTALLATION

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo-

sote, ashes and loose paint by a 

qualified chimney cleaner. Creo-

sote will ignite if highly heated. 

A dirty chimney flue may create 

and  distribute  soot  within  the 

house. Inspect chimney flue for 

damage. If damaged, repair flue 

before operating appliance.

NOTICE: Installation, service, and 

repair of this appliance must be 

performed by a qualified installer, 

service  agency,  company  or 

gas  supplier  experienced  with 

this type of gas appliance. Only 

factory  authorized  components 

listed in these instructions may 

be used in accordance with the 

manufacturer’s instructions and 

all  codes  and  requirements  of 

the authority having jurisdiction. 

Any modifications to this kit, or 

use of unauthorized components 

or accessory items will void the 

manufacturer’s warranty, and may 

result in a hazardous condition.

FLUE OPENING SPECIFICATIONS

Note:

 This vented appliance must be installed only 

in a solid-fuel burning fireplace with a working flue 

and constructed of noncombustible material.
The charts in Figure 2 indicate technical information 

regarding the installation of your gas log set. Please 

make sure that all of the specifications shown are 

applicable before installation is attempted.
The fireplace must include a working flue and 

venting system with the minimum openings shown 

in the Figure 2.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not 

natural  gas,  you  must  install  ON/OFF  Safety 

Valve/Pilot Kit (see 

Accessories

, page 13). Call 

dealer where you bought log set.
If the fireplace does not have a gas supply shutoff 

valve, one must be installed.

VENTING SPECIFICATIONS FOR 
INSTALLATION

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting: 

Light a tightly rolled newspaper on one end and 

place it at the inside front edge of the fireplace. 

Observe the smoke and be sure the vent is properly 

drawing it up the chimney. If the smoke spills out 

into the room, extinguish the flame and remove any 

obstruction until proper venting is achieved.
The chimney flue must remain open a minimum 

of  3"  at  all  times  during  the  operation  of  this 

log set. 

BURNER ORIFICE

LOG

SIZE

NATURAL

IN.   

NUM.

18"

.120

31

24"

.140

28

MINIMUM FIREBOX SIZES

MODEL FRONT

WIDTH

BACK

WIDTH*

DEPTH HEIGHT

SMS18

28"

18"

16"

18"

SMS24

32"

24"

16"

18"

Model

Burner

Descrip-

tion

Btu Input

Natural 

Gas

Minimum 

Vent  

Opening

SMS18 18" Ramp

60,000

8" dia.

SMS24 24" Ramp

80,000

8" dia.

*At depth indicated

FUEL INLET PRESSURE

SPECIFICATIONS (W.C.)

Min.

Max.

NG

5.5"

10.5"

LP

11"

13"

Figure 2 - Technical Information Charts

Summary of Contents for Comfort Glow SYCAMORE SPLIT SMS18

Page 1: ...e WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the...

Page 2: ...tilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently loc...

Page 3: ...d and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING D...

Page 4: ...stored under dusty conditions 8 Do not burn solid fuel in the replace after installing the log set Do not use this log set to cook food or burn paper or other objects 9 Do not use appliance if any par...

Page 5: ...e make sure that all of the speci cations shown are applicable before installation is attempted The replace must include a working ue and venting system with the minimum openings shown in the Figure 2...

Page 6: ...p within reach for test gauge hook up NPT tap must be upstream from log set see Figure 4 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning...

Page 7: ...d Burner Inlet Venturi Attached to Pan Bottom Gas Connector Tube Figure 6 Connecting Gas to Appliance Adapter Fitting Burner Inlet Fitting Factory Installed 3 Check all joints from gas meter to equipm...

Page 8: ...serve the individual tongues of ame on the burner Make sure that all ports are clear and produc ing ame evenly across the burner If any ports appear blocked clear them by removing the burner manifold...

Page 9: ...P Follow the safety information column 1 If you don t smell gas go on to the next step 4 Light a match and lay it on top of the pan material about 2 from the end of the sup ply side of the pan 5 Slowl...

Page 10: ...ing please have your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com REPLACEMENT PARTS Note Use only original replacement par...

Page 11: ...2 Adjust damper wide open and or have replace and vent ing professionally cleaned and checked 3 Separate the logs to allow more ame passage 4 Removeanyforeignitemsfrom the ame pattern and or check fo...

Page 12: ...ace control valve 1 Locate and correct all leaks see Checking Gas Connec tions page 7 OBSERVED PROBLEM Log set produces a clicking tick ing noise just after burner is lit or shut off Log set produces...

Page 13: ...only 3 pine cones per box ASH BED MATERIAL VERMICULITE GA9750A Not Shown For all models Use for rebox decoration only GLOWING EMBERS GA9950A Not Shown For all models Use for rebox decoration only SIL...

Page 14: ...www desatech com 117536 01B 14 ILLUSTRATED PARTS BREAKDOWN MODELS SMS18 AND SMS24 1 8 9 10 23 13 11 17 16 15 22 21 20 3 2 4 5 6 7 12 14 18 19...

Page 15: ...1 8 901242 01 901242 01 Damper Clamp Std Assy 1 9 11209 11209 Nut 10 24 2 10 117244 01 117244 02 Log Grate 1 11 117250 01 117251 01 Front Bottom Left Log 1 12 117250 02 117251 02 Front Bottom Right L...

Page 16: ...s war ranty The log set MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in orig...

Reviews: