14 Error messages / Operational status
If any errors or malfunctions occur during operation then an error message is displayed on screen. The
following errors could occur:
NOTE:
Errors are only displayed if the relevant accessories are present.
FAULT
REASON
SOLUTION
After assembling NO NEW
SCREW has been shot in.
The real SCREW TIME did NOT
exceed the MIN. DRIVER TIME.
Reduce the value of the MIN.DRIVER
TIME
(please see chapter 3)
RAIL SCREW SENS 1
The inlet control (for double spiral
bowls the first inlet) has not recognised
a part for 60 seconds.
No part has been recognised once
part assembly has begun.
RAIL SCREW SENS 2
The inlet control of the second inlet has
not recognised a part for 60 seconds.
No feed part has been recognised
once part assembly has begun.
This error is only relevant for double
spiral bowls.
HOSE SCREW SENS 1
The part presence control (for double
spiral bowls the first inlet) has not
recognised any parts after three
reloads.
HOSE SCREW SENS 2
The part presence control for the
second inlet has not recognised any
parts after three reloads.
This error is only relevant for double
spiral bowls.
If necessary refill the bowl,
Remove any parts which are jammed
in the guide rails, separator or feed
hose.
Check machine for dirt, sticky patches
or abrasive wear and if required clean
using air pressure or a clean cloth
(only use degreaser on uncoated
vibratory bowls).
Never grease feed parts.
FILL LEVEL
The bowl is empty or not filled
sufficiently.
Refill the vibratory bowl manually and if
required check linear hopper for
sufficient feed parts.