![Deprag SZG Controller 6 Operating Manual Download Page 37](http://html1.mh-extra.com/html/deprag/szg-controller-6/szg-controller-6_operating-manual_2485171037.webp)
SZG CONTROLLER 6 - ENGLISH
37
11.13.6 Bowl run time
The vibratory bowl run time is the length of time the vibratory drive remains active after separation is finished.
The bowl run time setting depends on the part length and the behaviour of the parts in the bowl. The guide
rails should always be full. There should be no gaps between the part heads. The bowl run is always carried
out after the new cycle delay. Basically for longer parts a longer bowl run time is required than for shorter
parts.
Minimum time :
0,4
sec.
Maximum time:
20,0
sec.
Steps:
0,2
sec.
11.13.7 Rail blow-off
The rail blow-off time is the length of time the air deflector valve on the bowl stays open after switching off
the vibratory drive. As standard the air shot is set to start at the same time as the vibratory drive.
Minimum time:
0
sec.
Maximum time:
1,0
sec.
Steps:
0,1
sec.
11.14
Password
In menu section CHANGE PASSWORD a password for the menu can be set or changed. The standard
password is 0000. Any value from 0001 to 9999 can be set. Use the buttons
and
to set the first
number. Confirm the number with
and then set the other numbers in the same way. After entering and
confirming the final number with the button
the menu will be closed and the password saved.
Press the button
to leave the menu section without saving the password.
If access to the menu should be allowed without password entry then set the password to 0000.
11.15
Language
The controller software is available in several languages. The language can be selected via menu section
LANGUAGE. Use the buttons
and
to move through the languages available. The current language
is marked by an asterisk. Press the button
to select the language you want for the display, an asterisk is
set. Use the button
to leave the menu section and the menu is now displayed in the chosen language.
11.16
Display
In menu section DISPLAY you can select the display screen which should appear during normal operation.
Use the buttons
and
to move through the options. The current selection is marked by an asterisk(*).
Press the button
to select the required option and an asterisk is set. Use the button
to leave the
menu section. After leaving the menu the selected display screen appears.
11.16.1 STANDARD
On this screen only the number of the current user is displayed.