![Denyo DCA-25USI Instruction Manual Download Page 51](http://html1.mh-extra.com/html/denyo/dca-25usi/dca-25usi_instruction-manual_2485064051.webp)
7 - 2 Connection of booster cable, and installation
When the engine is started using booster cables, connect the cables as follows.
(1) Connection of booster cable
Ф Connect the clip of the booster cable "A"
to the te rm in al"+" of the machine in trouble.
© Connect the other clip of the booster cable
"A" to the te rm in al"+" of normal machine.
® Connect the clip of the booster cable "B"
to th e terminal "B" to the terminal
11 of
normal machine.
© Connect the other clip of the booster cable "B
to the engine block of the machine in trouble.
battery of
normal machine
@
4+)*
battery of the machine in trouble
____________
Щ
®
engine block of the machine in trouble
—
battery of
normal machine
(2) Removal of booster cable
Ф Remove the clip of the booster cable"B"
connected to the engine block of the machine
in trouble.
© Remove the clip of the booster cable "B"
connected to the t e r m i n a l " of normal machine.
© Remove the
C lip O f
the booster cable "A"
engine block of the machine in trouble
connected to the term in al"+" of normal machine.
® Remove the clip of the booster cable "A"
connected to the terminal "+" of the machine
in trouble.
battery of the machine in trouble
® .
_ ©
(3) Caution on handling of booster cable
ф Use booster cables and clips of the size that matches the size of battery.
© The battery used for normal machine should be the same in capacity as the battery
of the machine in trouble.
© After connection, check that clips are firmly connected.
@ When connecting booster cables, make sure that the term in al"+" does not
touch the t e r m i n a l ".
© The engine block should be connected at a place more than 30cm away from the
battery.
-