![Denyo DCA-25USI Instruction Manual Download Page 26](http://html1.mh-extra.com/html/denyo/dca-25usi/dca-25usi_instruction-manual_2485064026.webp)
3—2 Installation of m achine
A
WARNING
ENGINE EXHAUST can kill.
■ Insufficient ventilation may lead to death due to
lack of oxygen or poisoning by exhaust gases.
* Do not use the machine in a place of poor ventilation
or in a place where exhaust gases stays.
* Do not use the machine indoors or in storehouse, tunnel,
ship hold, tank, etc. of poor ventilation.
* If it becomes necessary to use the machine in the
above places, the exhaust pipe should be extended
to a well ventilated place. In this case, use a ventilator
to ensure proper ventilation.
* Do not direct the exhaust outlet to nearby pedestrians
and houses.
[Note] vibration:
The engine, running, generates vibration during operation of the machine.
When installing the machine, be sure to observe the following points.
Ф Install the machine horizontally on a solid foundation.
Operation on an uneven place will generate unusual vibration.
© The machine should be installed on a substantial base to prevent claims from nearby
living people. For details of the vibration level of the machine and foundation work,
contact distributor or our office.
[Note] noise:
T he engine is running during operation of the machine.
If the door is open, much noise will be generated. But some noise will stay, when door is
closed.
When installing the machine, be sure to observe the following points.
* Close and lock the door after installation.
* We recomend to execute the measure for sound level to prevent claims from nearby
living people.
-
25
-